TABLE OF CONTENTS
1. INTRODUCTION
2. MAIN FEATURES
3. CAUTION
4. INSTALLATION
5. TESTING YOUR UPS
6. ERROR MESSAGE OF THE TEST
7. COMPUTER INTERFACE PORT
8. BUTTON FUNCTION ON FRONT PANEL
9. SPECIFICATIONS
1. INTRODUCTION
This is a high performance with compact shape line interactive Uninterruptible Power Supply (UPS) designed to protect
your computer from utility line failure.
In the event of utility failure (blackout), the UPS will rapidly transfer loads to an alternative power source which derives
power from battery set inside the UPS. The backup time for a Pentium III including 17" SVGA monitor is about 10
minutes with internal UPS model ALPHA 500 inT.
2. MAIN FEATURES
! Microprocessor based design.
! 'Green power' design with auto on/off function.
! Suitable for 5 1/4" disk size.
! Protection for overload & short circuit.
! Easy installation.
3. CAUTION
The UPS is suitable for personal computer & workstation only; and is to be installed inside a computer case.
After installation, please make sure that the maximum power requirement is not over the rated capacity of the
UPS. Red LED will be lighting and alarm will beep if the load is close to the rated value. Meantime, if the
overload is severe, the UPS will shut down immediately when a blackout happens in order to protect itself.
The UPS is shipped from the factory with fully charged internal batteries; however, the batteries may lose some
energy during delivery and storage. To ensure that the UPS will provide the expected run-time, the UPS must be
charged for at least 12 hours before your first use. Please simply turn on the UPS after installation when city
power is normal, and the batteries will be charged automatically.
11
4. INSTALLATION
Please follow the instructions below and refer to the hereunder drawing
4.1 Fix the metallic window plate on the rear panel of your computer case.
4.2 Plug the connector of the enclosed "Y" type power cord into the window plate.
4.3 Plug the connector of the power cord from the UPS with the matching connector of "Y" power cord.
4.4 The "Y" power cord has 2 outlets for your computer and monitor. To ensure that your computer will be protected
during a utility failure, the outlets of UPS must be connected with your computer and monitor, and apply the original
power cord of your computer as the input cord of the UPS. When the connection is completed, the UPS can be turned
on by one touch at the control button on the front panel.
"
-
IEC female to monitor
#
-
IEC female to computer
$
-
Switching power supply
%
-
Metallic window plate
&
-
DB9
'
-
IEC male from main
(
-
ALPHA 500 inT
5. TESTING YOUR UPS
5.1 Please have the UPS charged for 12 hours before test.
(Do not have to turn on your computer, just keep the city power connected to the UPS and turn on your UPS - green
LED will be on.)
5.2 In normal mode of UPS, turn on your computer, push the UPS button on the front panel for self-test. If it is OK,
green LED will be on. While if it is over loaded, the UPS will alarm. Or if the battery level is low, it will emit quick beep
for several seconds and stay in normal mode for recharging.
Please also refer to the, "LED/Alarm Indication" in item 6.5.
5.3 Push the button for 4sec, and check if the UPS can be turned-off manually.
5.4 Push the button again to turn on the UPS, then UPS will enter stand-by status, and finish the test.
12