Bosch FSA 760 Instrucciones De Funcionamiento página 26

Analizador de sistemas de vehículo
Ocultar thumbs Ver también para FSA 760:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 40
en
2� | FSA ��� �dition | Technical data
8.1.2
Multimeter
Measuring functions
Speed
U battery
U term. 15
U-DC/AC
min./max.
I-1000 A
I-30 A
Resistance
(R Multi 1)
Pressure P-air
Oil temperature
Air temperature
Fluid pressure
8.1.�
Oscilloscope
Trigger system:
R
Free Run (non-triggered run at ≥ 1 s).
R
Auto (curve output, also without trigger).
R
Auto level (like Auto, trigger threshold at signal center).
R
Normal (manual trigger threshold, curve output with
trigger result only).
R
Single sequence.
Trigger edge:
R
Edge (pos. / neg. on signal).
Trigger sources:
R
Engine (trigger on cylinder 1 ... 12 using trigger
clamp, clamp 1, KV sensor).
R
External trigger via clamp 1_1 cable or trigger clamp.
R
Multi measuring cable CH1 / CH2.
Pre-trigger percentage:
R
0 to 100 %, can be shifted with mouse.
Recording modes:
R
MaxMin (Peak/Glitchdetect).
R
Interference pulse recording.
R
Sample (equidistant scanning).
Memory operating modes and curve output modes:
R
Roll mode (single point display) with continuous storage
of signals when X deflections ≥ 1 s.
R
Legend mode (curve display) with continuous storage of
signals when X deflections ≥ 1 ms.
R
Normal mode with storage of last 50 displayed
curves when X deflections < 1 ms.
1 689 989 078
|
2012-01-20
Measuring ranges
Resolution
as for engine test
0 - 72 V
0,01 V
0 - 72 V
0,1 V
±200 mV – ±20 V
0,001 V
±20 V – ±200 V
0,01 V
±1000 A
0,1 A
±30 A
0,01 A
0 – 1000 Ω
0,001 Ω
1 kΩ – 10 kΩ
0,1 Ω
10 kΩ – 999 kΩ
100 Ω
0,2 hPa – 2500 hPa
0,1 hPa
-20 °C – 150 °C
0,1 °C
-20 °C – 100 °C
0,1 °C
0 – 10000 hPa
10 hPa
Measuring system:
R
8 measuring functions.
$
$
$
$
$
$
$
$
R
Signal range selectable: entire curve or between
cursors.
Zoom:
R
A curve sector can be selected for horizontal and
vertical enlargement.
Cursor:
R
Various cursors with display for
$
$
$
$
Comparison curves:
R
Store, load, comment, pre-setting of scope setup for
live curves.
Storage functions:
R
Scrolling back and forth.
R
Search functions e.g. MinMax, pulse duty factor.
Sensors
Connecting cable B+/B–
Connecting cable terminal 15
Multi measuring cable CH1 / CH2
Current clamp 1000 A
Current clamp 30 A
Multi measuring cable CH1
Air pressure sensor
Oil temperature sensor
Air temperature sensor
Fluid pressure sensor,
Oil pressure sensor
Average value.
Effective value.
Min.
Max.
Peek to peek.
Pulse.
Pulse duty factor.
Frequency.
x1, x2
delta x
y1 and y2 (channel 1)
y1 and y2 (channel 2)
Robert Bosch GmbH

Publicidad

Tabla de contenido
loading

Tabla de contenido