Pre-flashing time adjustment
Adjustment of phase displacement time while opening
Adjustment of phase displacement time while closing
Collectivity function: if it is activated it deactivates both opening and closing inputs for the whole duration of
automatic opening and closing
Ram blow function: it pushes the motors closed for one second before each opening movement, so as to ease
the electric-lock release
"Reversal" mode selection (during the manoeuvre a command impulse reverse the mouvement) or "step by
step" (during the manoeuvre a command impulse stops the mouvement). A next impulse restart the operator
to the opposite direction.
PHOTO 1
PHOTO 2
Operation mode selection of the warning light output:
If = 0 "fix warning light" (output always ON when the gate is open, OFF after a closing operation),
If> 1 "courtesy light" (output ON during each movement, OFF when the motor stops, after the setting delay).
Searches for end of stroke while opening too: when activated, operators stop only at their arrival et the end
of stroke, also while opening.
Warning: During the emergency operation (rESP), the motor executes the first maneuver while opening. In
addition, if any limit switches, the parameter is forced to 1.
"soft start" function: motors accelerate gradually until they reach the set speed, avoiding sudden departures.
Warning: For operators without encoder, the parameter will be ingnored.
Adjust the inversion on obstacle period (detected by internal anti-crushing sensor or by the safety input when
activated): If = 0 it makes a complete inversion, if> 0 indicates the duration (in seconds) of the run, after
inversion resulting from detection of an obstacle during the opening.
Adjust the inversion on obstacle period (detected by internal anti-crushing sensor or by the safety input when
activated): If = 0 it makes a complete inversion, if> 0 indicates the duration (in seconds) of the run, after
inversion resulting from detection of an obstacle during the closing.
Facilitation manual release: If≠0, after detecting the locking stop, the engine reverses for a brief time to
release the pressure on it, and thus facilitate the manual release. The set value shows the length of the
inversion. If=0 function disabled
Adjustment of the opening stroke margin: it adjusts the duration of the last part of the stroke during which an
obstacle is interpreted as a stroke, blocking the motor without performing the inversion.
For motors with encoders, the set value indicates the number of revolutions of the rotor; while for motors
without encoder, the value is expressed in% of the maximum stroke.
Warning: for motors without encoder, if P035 (duration slow-down while opening) is >10%, it forces the
stroke detection margin so that it's the same than the slow-down.
Adjustment of the closing stroke margin: it adjusts the duration of the last part of the stroke during which an
obstacle is interpreted as a stroke, blocking the motor without performing the inversion.
For motors with encoders, the set value indicates the number of revolutions of the rotor; while for motors
without encoder, the value is expressed in% of the maximum stroke.
Warning: for motors without encoder, if P036 (duration slow-down while closing) is >10%, it forces the stroke
detection margin so that it's the same than the slow-down.
44
PHOTO input functioning: If=0: photocell enabled while closing and starting when the gate is
stopped; if=1 photocells are always enabled; if=2 photocells are enabled while closing only.
When enabled, its activation provokes: the inversion (while closing), the stop (while opening)
and prevent the starting (when gate is closed).
If=3-4-5, the operation is the same as the values 0-1-2 but with "close immediately" enabled:
in any case, during the opening and/or the pause time, removal of a possible obstacle causes
the gate automatically closes after a fixed delay of 5 sec.