Blanco BC GF 3500 Manual De Uso página 33

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 74
TABLE OF ALARM INDICATIONS
Alarm
ALL
Thermocouple TCJ has failed or is
Err
The appliance switches to stand-
Er3
The appliance switches to stand-
Er4
The appliance switches to stand-
The appliance switches to stand-
Cause
Safety thermostat with automatic
reset tripped.
not properly connected.
Improper use of the appliance,
such as sudden changes in
temperature (thermal shock).
by status.
Electronic circuit board
diagnostics tripped.
Electronic circuit board heat
sensor tripped.
by status.
Fan malfunction.
by status.
Air intake line blocked.
by status.
- 13 -
Remedy
Allow the appliance to cool and
return it to ON status.
Important
If the problem persists, con-
tact the After Sales Service.
Important
Contact
the
after-sales
service.
Check the condition of
thermocouple TCJ and the
electrical connections.
Allow the appliance to cool and
return it to ON status.
Replace the electronic
circuit board
Important
Contact
the
after-sales
service.
Allow the appliance to cool and
return it to ON status.
Important
If the problem persists, con-
tact the After Sales Service.
Important
Contact
the
after-sales
service.
Check the condition of the fan and
the electrical connections.
Clean the air intake lines
Important
If the problem persists, con-
tact the After Sales Service.
IT
GB
DE
FR
ES
English

Publicidad

Tabla de contenido
loading

Productos relacionados para Blanco BC GF 3500

Este manual también es adecuado para:

Bc gf 4200Bc gr 3500Bc gr 4200

Tabla de contenido