Saving and retrieving a pattern
1. Start the recording by pressing the "Start" button.
2. Use the arrow keys to navigate the camera to the
desired image sections and positions.
3. Save the recording by pressing the "Stop" button.
4. Click on the "PTZ" button and in the "General"
tab, select the position on the keypad. Press the
"Start Pattern" button to go to the saved pattern.
Linear scan
1. Use the arrow keys to navigate the camera to the
desired image sections and positions.
2. Press the "Left Limit" / "Right Limit" button to
define the maximum horizontal value.
3. Click on the "PTZ" button and in the "General"
tab, select the position on the keypad. Press the
"Start Pattern" button to go to the saved pattern.
PTZ Settings
The protocol settings for the PTZ camera can be set
here. When using an HD TVI camera, the settings are
automatically detected. Protocol for HD TVI is ABUS-C
(Coaxitron). Select another protocol when using an
analogue PTZ camera.
Parameter
Setting
Camera
Select the camera channel
Baud Rate
Define the transmission rate
Data Bit
Standard 8
Stop Bit
Standard 1
Parity
No standard
Flow Ctrl
No standard
PTZ Protocol
Select the PTZ protocol
Address
Select the camera ID
101
Motion
Select the camera channel to be processed under
"Camera".
Put a tick by Motion Detection and with the mouse drag
one or more windows for the detection zone.
Alternatively, by pressing the "Full Screen" button, the
whole picture area for motion detection can be marked.
Note
To record with the aid of motion detection, you
must set up the schedule under Record.
When there are pixel changes in live view, motion
detection activates the camera. By setting the
"Sensitivity" slider, the resolution pattern can be
adapted for each individual camera.
Trigger Channel
When you click on "Settings", the Trigger Channel tab
will appear (only for motion detection):
Select one or more camera channel(s) to react in the
event of an alarm.
Confirm the settings by clicking on Apply and exit the
menu by clicking on OK.
Camera