Max. working area
Air flow step 1
Air flow step 2
Dehumidifying at 20˚C and 70% r.h.
Dehumidifying at 30˚C and 80% r.h.
Power at 20˚C and 70% r.h.
Power consumption at 20˚C and 70% r.h.
Refrigerant
Charge
Weight
Voltage
Frequency
Current
IP Code
Dimensions in mm, L x Bx H
*Technical changes and improvements may occur. All values are approximate and may vary due to external circumstances such as
temperature, ventilation and humidity.
PROBLEM
SOLUTION
Dehumidifier does not start
-
Check that dehumidifier is connected to electricity and that fuse has not gone
-
If the warning light is on, check that the water reservoir is empty and correctly placed in the dehumidifier.
Check that float is free
-
Check that hygrostat is working. Dehumidifier should start when hygrostat is in Maximum position
Does not dehumidify
-
Check that fan is spinning
-
Check that air can flow freely through the dehumidifier. Front grid and air filter should be clean and dehumidifier should stand
20-30cm from wall
-
Listen for sound of compression, but bear in mind that the dehumidifier may be in a dehumidifying cycle, when the compression stops. Wait initially for about 35
minutes.
-
Check that a thick coating of ice has not formed on the cooling coils.
High noise level
-
Increase distance between dehumidifier and surrounding surfaces
-
Cooling coils may be in contact with one another and cause vibration. Disconnect dehumidifier from electricity and separate coils
Ice formation on cooling coils
-
Remove air filter at rear of dehumidifier and check that no dust or fluff is obstructing passage of air through machine
The Led is flashing in green
- To low temperature- increase room temperature.
If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier
TECHNICAL DATA
DSC50FM
100m
2
256m3/h
520m3/h
8,0 L/ 24h
13,5 l/24h
145 W
3,5kWh/24 h
R290
100 g
22kg
230V
50Hz
1,1 A
X1
495x345x527
Operating Instructions
GB