Table 5: Reasons for jams (continued)
Feeder Motor Fault
Detected
Scan Bed Motor Fault
Detected
Stacker Motor Fault
Detected
ID1 Assist Verify Jammed
Servo Fuse 1 Fault
Detected
Servo Fuse 2 Fault
Detected
Roller Bed Fan Fault
Detected
Feeder Fan Fault
Detected
142
This event can occur during a job activation of
the feeder motor and a stall, over-current,
under-current, thermal warning or thermal
shutdown is detected by the stepper controller.
This event can occur during a job activation of
the scan bed motor and a stall, over-current,
under-current, thermal warning or thermal
shutdown is detected by the stepper controller.
This event can occur during a job activation of
the stacker motor and a stall, over-current,
under-current, thermal warning or thermal
shutdown is detected by the stepper controller.
This event can occur during a run when the
sensor ID1 ASSIST VERIFY sensor is blocked
longer than the configurable amount of time has
allowed. The id assist sensor jammed time
(5000) machine parameter configures this
timeout. The default is 5000 milliseconds or 5
seconds.
This event can occur during a run when the fuse
for the servo motor, which controls the upstream
or right-hand pre-feed arm, is detected to be
open or blown.
This event can occur during a run when the fuse
for the servo motor, which controls the
downstream or left-hand pre-feed arm, is
detected to be open or blown.
This event can occur during a run when the fan
for the roller bed motor is not detected as
operating.
This event can occur during a run when the fan
for the feeder motor is not detected as
operating.
Falcon+ Operator Manual