Descargar Imprimir esta página

Flexim WI-400 Manual Del Usuario página 75

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Supplement to operating instruction - ENGLISH
Installation of the jaws
Notice!
For the installation on a horizontal pipe, select a measuring point where the transducers can be mounted on the side of
the pipe, allowing the sound waves to propagate in the pipe horizontally. Thus, solid or liquid deposits on the bottom of
the pipe or gas bubbles in the upper part are prevented from influencing the propagation of the signal.
• Place both jaws on the guiding rods, see Fig. 4.32.
• Adjust the distance WI Clamp dist., see section 5.2 and Fig. 4.33.
• Tighten the screws of the jaws, see Fig. 4.32.
Fig. 4.32:
Installation of the jaws
1 – screw
Fig. 4.33:
Distance of the jaws (side view)
• Place the jaw and the guiding rods on the pipe, see Fig. 4.34.
Fig. 4.34:
Positioning of the jaws on the pipe
• Push the chain into the hooks of the first jaw (inner cog), see Fig. 4.12 and Fig. 4.35.
• Place the chain around the pipe and tighten it.
• Push the end of the chain into the second hook of the jaw.
• Fix the chain and the on the pipe by slightly tightening the nuts.
• Repeat the steps for the second jaw.
2018-01-19, SUFLUXUS_WIV4-3EN
1
WI Clamp dist.
WaveInjector WI-400
75

Publicidad

loading

Este manual también es adecuado para:

Fluxus f60xFluxus f70xFluxus f80xFluxus adm 8027