Maintenance
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
1
Thermostat Sensing Probe
2
Lint Screen
Monthly
Lubrication
Motor bearings, roller bearings and trunnion bearings
are sealed bearings and require no lubrication.
28
WARNING
50 – 170 POUND TUMBLERS
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
1
Figure 17
Lint Removal
Remove the exhaust duct from the exhaust thimble and
remove lint. If excessive lint is evident at the thimble,
further disassemble the duct work and remove lint.
Energy Saver Gas Models: Remove the cleanout cover
at the bottom of the vertical duct and clean out lint.
2
T046I
W002
T046I
M414462