A Appendix; Technical Data; General; Mains Connection - Rohde & Schwarz R&S IN4000A Manual Del Usuario

Tabla de contenido

Publicidad

FÖRSVARETS MATERIELVERK
R&S IN4000A

A Appendix

A.1 Technical Data
A.1.1

General

Property
Operating temperature
Cooling
Thermal protection
Relative humidity
Max. altitude
Sustainable pollution
Overvoltage environment
A.1.2

Mains Connection

Property
Input Voltage
Input Current
Input power
Input fuse
Leakage current
Safety standard
A.1.3

Battery Input

Battery input
Battery voltage
Battery current
Negative potential
Battery fuse
BATT signalling
User Manual 6105.5822.02 - 02
TEKNISK ORDER DRIFT
Value
U
≥ 100 V: -25 °C to +55 °C w/o derating
in
U
< 100 V: -25 °C to +50 °C w/o derating
in
Temperature controlled fans
Reset by cooling down
0 to 95 % (MIL-STD 810F method 507.4)
3000 m
Degree 2 (according to IEC-664-1 / EN60950)
Cat. 2 (according to IEC 60950-1)
Value
90 to 264 V
, 47 Hz to 63 Hz
AC
3.2 to 10 A
Max. 920 W
2 x F10A, 250 V
, 5 x 20 mm, internal
AC
<3.5 mA
EN60950
Value
max 27.5 V
DC
<27.5 A
Potential free
F30A, 75 V
, 6.3 x 32 mm, exchangeable
DC
No signalling
DF SAMBAND 100 023032
Appendix

Technical Data

22

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

6105.5800.02

Tabla de contenido