The selectable (set) humidity level has a range of 25% to 65% and is adjusted in
increments of 5%. Initially depressing the humidity button will display the current
humidity setting. Each additional press of the button increases the setting by 5%.
A set point of 65% RH operates the humidifier continuously regardless of the
ambient reading.
REFILL DISPLAY
When the base is empty, the display alternates the ambient room
humidity reading and "F" (FILL), indicating additional water is
required.
AUTO DRYOUT
At this time the unit will automatically switch into AUTO DRY OUT MODE and
continue to run on the lowest speed until the filter is completely dry. The fan will shut
off leaving you with a dry humidifier that is less prone to mold and mildew.
If AUTO DRY OUT MODE is not desired, refill the humidifier with water and the fan
will return to the set speed.
CHECK FILTER INDICATOR
The ability of any humidifier to efficiently supply humidity output relies heavily on the
condition of the wick (filter). As the wick loads with impurities it gradually loses its
wicking capability. When this happens, moisture output is reduced
and the humidifier has to work longer to satisfy the selected setting.
This humidifier has a "check filter" reminder timed to appear after
720 hours of operation. When the display shows an alternating "CF"
(CHECK FILTER) and ambient humidity setting at 5 second intervals
it is a reminder to check or change the wick.
NOTE: Some areas have high water mineral content requiring more frequent wick
changes.
Reset the Check Filter "CF" function each time you replace a wick by unplugging the
unit from the power source for 1-2 minutes, then plug it in again.
Refer to "Replacement of Wick" section below. If a build-up of deposits or severe
discoloration is evident, replace the wick to restore maximum efficiency.
CONTROL LOCK FEATURE
To avoid unwanted tampering with the humidifier settings the
controls can be locked.
CONTROL LOCK ACTIVATION PROCEDURE
After the humidifier functions have been set up, hold the power
button down for 5 seconds. The display will show "CL"( CONTROL
LOCK) for 2 seconds; release the power button and the control will resume the display
of the room humidity. The humidifier will continue to function with the locked in
settings. If buttons are operated while "CL" is active, the "CL" is displayed and
settings are unaffected.
CONTROL LOCK DEACTIVATION PROCEDURE
To deactivate the "CL" function simply press and hold the power button for 5
seconds. "CL" will flash at the rate of 1 second on and 1 second off for a period of 2
seconds and then resume the display of room humidity.
This will hold the float in an upward position and the fan will run until you turn the
power off.
NOTE: Be sure to reposition float retainer to the normal operating position (lowest
portion of the slot) before using the humidifier again. See diagram for proper
placement of the float retainer in the float retainer slot in the cabinet back.