2.5) Description of connections
Terminals
Functions
1-2
Phase - Neutral
3
Earth
4
Earth
5-6
Motor
7-8
Encoder
9-10
Flashing lamp
11-12
Electrical block/Suction pad 24Vdc electrical block/suction pad output max. 500mA
13-14
Phototest
15-16
24Vdc
17
Common
18
Sca
19
Cor
20
Man
21
Stop
22
Photocell
23
Photo 2
24
Step-by-step
25
Open
26
Close
27
Partial open
41-42
2° Radio Ch
43-44
Aerial
+ -
Battery
Description
Mains power input
Control unit earth connection
Motor earth connection
36Vdc motor power input
Motor encoder input
24Vdc flashing lamp input max. 25W
Phototest output
24Vdc services power input max. 200mA
Common for all inputs
Door open lamp output (on when the door is open, off when it is closed, flashes
slowly during the opening manoeuvre, flashes quickly during the closing manoeuvre)
Courtesy lamp output (switches on when the manoeuvre begins and switches off 60
seconds after the manoeuvre has finished)
Maintenance lamp output
Input with STOP function (Emergency, shutdown or extreme safety)
Input for safety devices (photoelectric cells, pneumatic edges) affecting the closing
manoeuvre
Input for safety devices (photoelectric cells, pneumatic edges) affecting the opening
manoeuvre
Input with cyclical Open-Stop-Close-Stop operation
Input for opening movement with cyclical Open-Stop-Open-Stop operation
Input for closing movement with cyclical Close-Stop-Close-Stop operation
Input with cyclical Partial Open - Stop - Close- Stop operation
Output for the second radio receiver channel
Input for the radio receiver aerial
24 volt battery connection