• Make sure that the fixing zone is not subject to flooding. If necessary, mount
the product raised from the ground .
• Ensure that the space around the product enables easy and safe access.
• Make sure that all the electrical cables used are of the type listed in
Table 1 .
• Make sure that the automation is provided with mechanical stops on both
closing and opening .

2.2 - Product application limits

The product may be used exclusively with gearmotors listed in Table 3 .

2.3 - Typical system

Fig. 2a shows an example of an automation system set up with Nice components:
a - Control unit
b - Gearmotor
c - Flashing light
d - Photocell
e - Digital keyboard - Transponder reader - Key selector
f - Photocell post
g - Opening mechanical stops
h - Closure mechanical stops
i - Electric lock
Connection
A: CONTROL UNIT POWER cable
B: FLASHING LIGHT with aerial cable
C: BLUEBUS DEVICES cable
D: KEY-OPERATED SELECTOR SWITCH cable
E: GEARMOTOR POWER cable
F: ENCODER CONNECTION cable
G: ELECTRIC LOCK CONNECTION
Note 1 – If the power cable is longer than 30 m, a cable with a larger cross-section is required (3 x 2.5 mm
of the automation .
Note 2 – If the Bluebus cable is longer than 20 m (up to max. 40 m), a cable with a larger cross-section is required (2 x 1 mm
Note 3 – These 2 cables can be replaced by a single 4 x 0 .5 mm
Note 4 – These 2 cables can be replaced by a single 5 x 1 .5 mm
IMPORTANT! – The cables used must be suited to the installation environment.
3

ELECTRICAL CONNECTIONS

The electrical connection of the various devices (photocells, digital keyboard,
transponder card readers, etc .) contained in the automation with the control
unit must be made by means of the Nice "Bluebus" system .
3.1 - Description of electrical connections (fig. 6)
AERIAL
input for the radio receiver aerial
FLASH
output for 1 flashing light with 12V (maximum 21W) bulb . [*]
ELS
output for 12Vac (maximum 15VA) electric lock . [*]
S.C.A.
"Open Gate Light": output for 1 indication lamp (24V maximum
4W) . [*]
BLUEBUS
input for compatible devices (MOFB, MOFOB, MOB and
MOTB); they are connected in parallel using two conductors
through which both the electricity supply and the communi-
cation signals travel; no polarity needs to be observed . The
electrical connection to be used is of the parallel type and no
polarity needs to be observed . During the learning stage, the
control unit will recognise individually all devices connected to it
thanks to a unique code. Each time a device is added or elimi-
nated, it will be necessary to make the control unit perform the
learning operation (see paragraph 3 .6) .
STOP
input for devices that cause the immediate interruption of the
manoeuvre in progress (with a short reverse run); NO and NC
contacts, as well as devices with 8 .2 kΩ constant resistance
output (sensitive edges) can be connected to this input . Each
device connected to this input is recognised individually by the
control unit during the learning stage (paragraph 3 .6); in this
stage, if the control unit detects any variations with respect
to the learned state, it causes a STOP . One or more devices
of the same or different kinds can be connected to this input:
– connect a number of NO devices in parallel without quantity
limits;
– several NC devices can be connected in series, with no limits
as to quantity;
2 – English
TABLE 1 - Technical specifications of electrical cables (fig. 2b)
Cable type
1 cable 3 x 1,5 mm
1 cable 2 x 0,5 mm
1 shielded cable type RG58
1 cable 2 x 0,5 mm
2 cables 2 x 0,5 mm
1 cable 3 x 1,5 mm
1 cable 2 x 1 mm
1 cable 2 x 1 mm
2
cable .
2
cable .
These parts are positioned according to a typical standard layout . With refer-
ence to fig. 2a, locate the approximate position for installation of each com-
ponent making up the system . Important – Before installation, prepare the
electrical cables needed for your system, referring to fig. 2b and "Table 1 -
Technical characteristics of electrical cables" .
Important – During installation of ducting for electrical cables and the introduc-
tion of cables into the control unit enclosure, be aware that due to possible
water deposits in the junction boxes, the connecting ducts may form conden-
sation inside the control unit which is liable to damage the electronic circuits .

2.4 - Installation of control unit

To mount the control unit, proceed as shown in fig. 3:
01. Open the control unit box by undoing the relevant screws (fig. 3-A);
02. Prepare the electrical cable routing holes (fig. 3-B);
03. Mount the box (fig. 3-C);
04. The electrical connections can now be made: see chapter 3 .
Important! – To prepare the inlets for the electrical cable ducting, holes must
be drilled in the lower side of the control unit box . Note – If necessary, the
lateral cable inlet may be used, but only with the aid of suitable duct fittings .
To install the other devices present in the automation, refer to the relevant
instruction manuals .
Maximum admissible length
30 m (note 1)
2
2
20 m
20 m (less than 5 m recommended)
20 m (note 2)
2
(note 3)
2
50 m
(note 4)
2
10 m
(note 4)
2
10 m
2
10 m
) and safety earthing is necessary in the vicinity
2
– connect 2 devices with 8 .2 kΩ constant resistance output in
parallel . If there are more than 2 devices, they must be connect-
ed in a cascade with just one 8 .2 kΩ termination resistance;
– connect 2 NO and NC devices in parallel, placing a 8 .2 kΩ
resistance in series on the NC contact (this also allows for a
combination of three devices NO - NC and 8 .2 kΩ)
P.P.
input for devices which control Step-by-Step manoeuvres . NO
contacts can be connected to this input
OPEN
input for devices which control only opening manoeuvre . NO
contacts can be connected to this input
CLOSE
input for devices which control only closure manoeuvre . NO con-
tacts can be connected to this input
ENC1
input encoder – gearmotor 1 (terminal 1, 2); it is not necessary
to observe any polarity
ENC2
input encoder – gearmotor 2 (terminal 4, 5); it is not necessary
to observe any polarity
M1
output for gearmotor 1 (terminal 7, 8, 9)
M2
output for gearmotor 2 (terminal 10, 11, 12)
[*] The FLASH, ELS and S .C .A . outputs can be programmed with other
functions (see "TABLE 5 - 1st level functions"; or via Oview programmer, see
chapter 7 .2) .

3.2 - Electrical connections of MC824H control unit

After mounting the control unit box and preparing the electrical cable holes
(chapter 2 .4 and fig . 3), make the electrical connections:
IMPORTANT!
– All electrical connections must be made with the unit disconnected
from the mains power supply and with the buffer battery disconnected,
if present in the automation.
– Connections must be made exclusively by qualified personnel.
– The electrical power line must be fitted with a device that enables complete
disconnection of the automation from the mains . The disconnection device
must have a gap between contacts that ensures complete disconnection in
the conditions of overvoltage category III, in compliance with installation regula-
tions . If necessary, this device guarantees rapid and safe disconnection from
the mains, and therefore should be located in view of the automation . However,
if located in a concealed position, it must have a system that blocks against
inadvertent or unauthorised reconnection to prevent all risks . The disconnec-
tion device is not supplied with the product .
) .