Best Witch MET 60 Instrucciones De Uso página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
English
! The appliance must be installed by a qualified person in compliance
with the instructions provided.
!
Wear gloves when carrying out installation and maintenance
operations.
If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a
hazard.
Warning: Failure to install the screws or fixing device in accordance with
these instructions may result in electrical hazards.
IMPORTANT: So as not to damage your product, during installation USE
ONLY THE SCREWS PROVIDED. Make sure these are used as shown in
the following instructions.
Prepare the power supply (see "Warning" sheet).
For the ducting version and version with an external motor, prepare the pipe
for air evacuation (see "Warnings" sheet).
FILTERING OR DUCTING VERSION ?
The hood may be in filtering or in ducting version. Decide from the outset
which type is to be installed.
For better efficiency, we recommend installing the hood in the ducting
version (if possible).
Ducting version
The hood purifies the air and evacuates it to the outside through an exhaust
duct.
Filtering version
The hood purifies the air and recycles the clean air back into the room.
CONTROLS
- If the hood is left on (lights and/or motor), after 10 hours in the absence of
commands from the user, it will automatically switch to OFF condition with all
services switched off. In hoods with voltage 120V/60Hz this function is not
active.
- The Buzzer emits a "beep" each time that a command is set from the keyboard
or remote control (optional).
- In the event of interruption of power during the hood, if you restore the hood
in the OFF state, then the engine must be reactivate manually.
Controls of Fig. 11:
PU1: ON/OFF Lights
PU2: ON/OFF Motor 1
speed
st
PU3: ON/OFF Motor 2
speed
nd
PU4: ON/OFF Motor 3
rd
speed
PU5: Timer
5' timer function:
Pressing PU5 the 5' timer function is activated. The LED starts blinking to
display this function. After five minutes of operation the motor is turned
off. If you change the speed while the timer is running, the function is NOT
deactivated. To deactivate the function, press the blinking key.
Buzzer: Each time the key is pressed, a beep is sounded.
Filter alarm:
After 30 hours of motor operation, the grease filter alarm is activated (all
the LEDs come on). The alarm is activated when the motor is off and
remains displayed for 30". To deactivate the alarm, press one of the keys
for 2" during alarm display. After 120 hours of motor operation, the charcoal
filter alarm is activated (all the LEDs blink). The alarm is activated when the
motor is off and remains displayed for 30". To deactivate the alarm, press
one of the keys for 2" during alarm display.
MAINTENANCE
! Before cleaning or maintenance cut the power.
Cleaning the hood
WHEN TO CLEAN IT: clean in relation to use, at least every 2 months to
prevent the risk of fire.
EXTERNAL CLEANING: use a cloth moistened in lukewarm water and
neutral detergent (for painted hoods); use specific products for steel,
copper or brass hoods.
INTERNAL CLEANING: use a cloth (or brush) soaked in denatured ethyl
alcohol.
WHAT NOT TO DO: do not use abrasive or corrosive products (e.g. metal
sponges, brushes, too hard brushes, very aggressive detergents, etc.)
Cleaning the grease filters (F)
WHEN TO CLEAN IT: clean in relation to use, at least every 2 months to
prevent the risk of fire.
HOW TO CLEAN THE FILTERS: hand wash or in the dishwasher using a
neutral detergent. If washing in the dishwasher, possible discoloration of the
filters does not in any way compromise their functioning.
Replacing the charcoal filter
(for filtering version only)
WHEN TO REPLACE IT: replace in relation to use, at least every 6
months.
HOW TO REMOVE IT: Remove the 2 filter clips (M) and then remove the
charcoal filter.
Lighting
If the light spot is damaged, it must be replaced only by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
MALFUNCTIONS
If something appears not to be working properly, do the following simple
checks before calling Technical Service:
• If the hood is not working:
Check that:
- The power has not been disconnected.
- A speed has been selected.
• If the hood performs inefficiently:
Check that:
- The motor speed selected is sufficient for the amount of smoke and
vapours released.
- The kitchen is sufficiently ventilated to allow air intake.
- The charcoal filter is not worn (hood in filtering version).
• If the hood has turned off during normal functioning:
Check that:
- The power has not been disconnected.
- the omnipolar disconnection device has not tripped.
Components not provided with the product
F
M

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bhp66250ga

Tabla de contenido