8‐2
Technical Data
Electrical Specifications
Item
Hose/gun heating capacity
Control temperature range
Control temperature accuracy
International Protection (IP) rating
Input voltage tolerance
NOTE
A:
Dependent on melter configuration and addition of optional hose/gun modules
B:
Flow set‐point at RTD
Pump Specifications
Air pressure while running
Minimum air pressure
Viscosity range
Maximum hydraulic pressure
Air consumption at 415 kPa (60 psi) and maximum pump
speed
Displacement
Maximum speed
Melter Power Requirements
Melter
P4
P7
P10
Part 1024496_05
Item
Number of
1‐Phase Power
Hose/Guns
Draw (Amps)
2
4
2
4
2
4
6
Data
2, 4, or 6 hose/gun pairs
40 to 230 °C (100 to 450 °F)
1 °C
IP54
+10%, -15%
70 to 689 kPa (10 to 100 psi)
0.7 bar (10 psi)
800 to 10,000 cps
15:1 pump: 10.3 MPa (1500 psi)
6:1 pump: 4.14 MPa (600 psi)
46 l/min. (1.6 scfm)
7.20 ml/stroke ( 0.44 in
90 strokes/min.
Without Neutral
17
26
18
27
18
27
35
Data
3
/stroke)
3‐Phase Power (Amps)
With Neutral
15
9
23
17
16
10
24
17
16
10
24
17
31
18
E 2011 Nordson Corporation
Note
A
B