Using Nordson Configuration Manager; Saving And Restoring Melter Settings - Nordson ProBlue P4 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

C‐6
Melter Communications

Using Nordson Configuration Manager

Configuration Manager
desktop icon

Saving and Restoring Melter Settings

Part 1024496_05
Configuration Manager is launched from your Windows desktop using the
icon shown to the left.
Use Configuration Manager when you want to...
S
copy melter settings from one melter to another melter
S
create and save more than one version of melter settings
S
upgrade or restore a melter's firmware
Configuration Manager communicates with your melter through a PC
connected to your melter's serial port. Once connected, Configuration
Manager offers the choice of saving settings, restoring settings, or upgrading
the melter's firmware.
The first time you download and install Configuration Manager, the latest
version of the melter's firmware is also downloaded.
Saving settings copies all current set‐point and operating parameter values
to your PC. Saved settings can be transferred back to the same melter or to
any other compatible Blue Series adhesive melter.
To save melter settings
1. Place the melter into the configuration mode by simultaneously pressing
the Standby and Setup keys.
"COnF" appears in the right display.
2. Double‐click the NCM icon on the Windows desktop.
The NCM dialog box appears.
3. Click Select Device.
The Select Product dialog box appears.
4. Select your melter from the list, and then click Ok.
The Select COM Port dialog box appears.
E 2011 Nordson Corporation

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Problue p7Problue p10

Tabla de contenido