Requirements For Operations At Raised Height; Grounding Requirements - mabe MMI12CABWCAAXM8 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

58
north america
appliance
amps(A))
10
13
18
25
30
40
8.
The size of the power cord, power cable, fuse, and switch needed is
determined by the maximum current of the unit. The maximum
current is indicated on the nameplate located on the side panel of the
unit. Refer to this nameplate to choose the right cable, fuse, or switch.
note:
Core number of cable refer to the detailed wiring diagram adhered on
the unit which you purchased.

requirements for operations at raised height

When carrying out installation at 2m or higher above the base level,
fasten to the outdoor unit, to prevent falling that could cause
personal injury or death as well as property loss.

grounding requirements

The air conditioner is the type I electrical appliance and must ensure a
reliable grounding.
Do not connect the grounding wire to a gas pipe, water pipe,
lightning rod, telephone line, or a circuit poorly grounded to the
earth.
The grounding wire is specially designed and shall not be used for
other purpose, nor shall it be fastened with a common tapping screw.
others
The connection method of the air conditioner and the power cord and
the interconnection method of each independent element shall be
The model and rating value of the fuse shall be subject to the
silkscreen on corresponding controller or fuse sleeve.
other regions
AWG
rated current
of appliance(A)
18
>3 y ≤ 6
16
>6 y ≤ 10
14
>10 y ≤ 16
12
>16 y ≤ 25
10
>25 y ≤ 25
8
>32 y ≤ 40
nominal cross-
sectional area(mm )
0.75
1
1.5
2.5
4
6

Hide quick links:

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido