Flush installation
Install Appliance
Electrical Installation
The ovens is dual rated, designed to be connected to
either 208/240V AC, 60 Hz, 4 wire, single-phase power
supply.
Model
HBE5452UC
The electrical supply should be a 4-wire single-phase AC.
Install a suitable conduit box (not furnished). An
appropriately-sized, UL-listed conduit connector must be
used to correctly attach the conduit to the junction box.
NOTICE: Local Codes may vary; installation, electrical
connections and grounding must comply with all
applicable local codes.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and
the bare ground wire from the oven to the white neutral
electrical supply wire.
8
Dedicated circuit required
20 AMP
* Flush installation requires a
22
/
" (560 mm) wide x 22
1
16
plate underneath the unit body.
CAUTION
9
The appliance must be disconnected from the
▯
power supply during all installation work.
The appliance must only be connected with the
▯
power cable provided.
Protection against contact must be ensured by
▯
the installation.
/
" (5 mm) high x
3
16
/
" (581 mm) deep base-
7
8