-Dismantle the HV-fan in accordance with the following
instructions:
Fig. 10.- Loosen the retaining screw (b) fixing the internalfront
cover (a).
Fig. 11.- Remove the internal front cover (a) by pressing the knobs
(c).
Fig. 12.-Loosen the 3 bolts (d) fixing the internal grille (e) and
separate it from the support plate (f).
-lnstall the HV-fan as follows:
Fig. 13.- Pull the internal grille (e) towards you and take the rubber
mountings (g) away from the screws (h).
Fig. 14.- Fix the threaded rods (n) to the screws (h) on the external
grille (e) with the threaded couplers (p) supplied and put back the
rubber mountings (g) on the rods.
Fig. 15.- From the outside, place the external grille (e) over the hole
in the wall. From the inside, turn and push the rubber mountings
(g) until they are located against the wall keeping the external grille
(e) in its correct position.
Fig. 16.- Mount the support plate (f) to the threaded rods (n) and
tighten the bolts (d) to suit the length of the rod sticking out from
the support plate (f).
Fig. 17.- Fix the support plate (f) to the wall and tighten bolts (d).
Fig. 18.- Depending on the position of the incoming electrical
cables, make a hole on the gland (i) on the front cover (a) or in the
gland (p) on the support plate (f), introduce the electrical cables
through the clamp (j) and connect to the terminal box (k).
Fig. 19.-Mount the internal cover (a) by slotting the retangular
openings (1) on the top of the cover (a) into the receivers (m) of the
support plate (f) until the two knobs (c) are correctly positioned.
Fig. 9.-Tighten the locking screw (b).
Ensure the shutter arm is located into the shutter slot when the
External grill is fltted. Finally check for correct running and shutter
operation.
Electrical wiring
Before proceeding with electrical connections, make sure it is
disconnected from the network.
Also, make sure that the impeller turns freely and there are no
obstructions in the fan inlet or outlet.
Means for disconnection must be incorperated in the fixed wiring in
accordance with the wiring rules. The electrical installation should
be made with a multipolar isolating switch with an opening
distance between contacts of at least 3 mm.
The HV-230 and HV-300 models can be connected via electrical
accessories CR-150 (Fig. 3) and REB-1R (Fig.D).
ATTENTION : if connected the CR-150 (Fig.B) keep in mind to
change the bridge between terminals 5-1 and 5-2.
Also it can be connected
according the Fig,C.
the device without any accessories
Maintenance
Before handling the fan, make sure it is disconnected from the
mains supply. Clean regularly with a soft cloth moistened with
water. Periodically check the state of the impeller. Do not clean
with pressure water jet.
Removal from service, disposal and recycling
The CEE norm and our commitment to future generations
require us to recycle waste material ; please deposit all remaining
elements of the packaging into containers for recycling, and carry
the equipment that has been replaced to the nearest waste centre
or your dealer.
Technical assistance
The extensive S&P Official Services Network guarantees competent
technical assistance anywhere in Spain.
If any anomalies are observed in the appliance, please contact any
of the Technical Services on the list to deal with your problem.
Any handling of the appliance by persons other than S&P Official
Services will lead to the guarantee being cancelled.