FUNCTIONAL DESCRIPTION
CAUTION:
• Always be sure that the tool is switched off and
unplugged before adjusting or checking function on the
tool.
Switch action (Fig. 1)
CAUTION:
• Before plugging in the tool, always check to see that
the switch trigger actuates properly and returns to the
"OFF" position when released.
To start the tool, simply pull the switch trigger. Release
the switch trigger to stop.
Speed change (Fig. 2)
The revolutions and blows per minute can be adjusted
just by turning the adjusting dial. The dial is marked 1
(lowest speed) to 6 (full speed).
Refer to the table below for the relationship between the
number settings on the adjusting dial and the revolutions/
blows per minute.
Number on
Revolutions per
adjusting dial
6
5
4
3
2
1
Selecting the action mode
Rotation with hammering (Fig. 3)
For drilling in concrete, masonry, etc., depress the lock
button and rotate the change lever so that the pointer
points to the
symbol. Use a tungsten-carbide tipped
bit.
Hammering only (Fig. 4)
For chipping, scaling or demolition operations, depress
the lock button and rotate the change lever so that the
pointer points to the
chisel, scaling chisel, etc.
CAUTION:
• Do not rotate the change lever when the tool is running
under load. The tool will be damaged.
• To avoid rapid wear on the mode change mechanism,
be sure that the change lever is always positively
located in one of the two or three action mode posi-
tions.
Torque limiter
The torque limiter will actuate when a certain torque level
is reached. The motor will disengage from the output
shaft. When this happens, the bit will stop turning.
CAUTION:
• As soon as the torque limiter actuates, switch off the
tool immediately. This will help prevent premature wear
of the tool.
6
Blows per
minute
minute
240
2,150
230
2,050
200
1,800
170
1,500
130
1,200
120
1,100
symbol. Use a bull point, cold
Indicator lamp (Fig. 5)
The green power-ON indicator lamp lights up when the
tool is switched ON. If the indicator lamp is lit but the tool
does not start, the carbon brushes may be worn out, or
the electric circuit or the motor may be defective. If the
indicator lamp does not light up and the tool does not
start, the ON/OFF switch or the mains cord may be
defective.
The red service indicator lamp lights up when the carbon
brushes are nearly worn out to indicate that the tool
needs servicing. After approx. 8 hours of use, the motor
will automatically be shut off.
ASSEMBLY
CAUTION:
• Always be sure that the tool is switched off and
unplugged before carrying out any work on the tool.
Side handle (Fig. 6 & 7)
CAUTION:
• Use the side handle only when chipping, scaling or
demolishing. Do not use it when drilling in concrete,
masonry, etc. The tool cannot be held properly with this
side handle when drilling.
The side handle can be swung 360° on the vertical and
secured at any desired position. It also secures at eight
different positions back and forth on the horizontal. Just
loosen the clamp nut to swing the side handle to a
desired position. Then tighten the clamp nut securely.
Side grip (Fig. 8)
CAUTION:
• Always use the side grip to ensure operating safety
when drilling in concrete, masonry, etc.
The side grip swings around to either side, allowing easy
handling of the tool in any position. Loosen the side grip
by turning it counterclockwise, swing it to the desired
position and then tighten it by turning clockwise.
Installing or removing the bit
Clean the bit shank and apply bit grease before installing
the bit. (Fig. 9)
Insert the bit into the tool. Turn the bit and push it in until
it engages.
If the bit cannot be pushed in, remove the bit. Pull the
chuck cover down a couple of times. Then insert the bit
again. Turn the bit and push it in until it engages.
(Fig. 10)
After installing, always make sure that the bit is securely
held in place by trying to pull it out.
To remove the bit, pull the chuck cover down all the way
and pull the bit out. (Fig. 11)
Bit angle (when chipping, scaling or demolishing)
The bit can be secured at 12 different angles. To change
the bit angle, depress the lock button and rotate the
change lever so that the pointer points to the "O" symbol.
Turn the bit to the desired angle. (Fig. 12)
Depress the lock button and rotate the change lever so
that the pointer points to the
that the bit is securely held in place by turning it slightly.
(Fig. 13)
symbol. Then make sure