Table "A": Technical Data
EQU-PF Model
Nominal cooling capacity (*)
rd
E.E.R. (3
step, 100%)
rd
E.E.R. (3
step, 100%)
EN 14511 05/11 (250kPa residual)
E.S.E.E.R.
E.S.E.E.R. +
E.S.E.E.R. EN 14511 05/11 (250kPa residual)
E.S.E.E.R + EN 14511 05/11 (250kPa residual)
rd
Sound power level (3
step, 100%) (***)
Scroll/step compressor
Circuits
Fans
Fan nominal air flow
Fan maximum available static head
Water side heat exchanger water content
Water side heat exchanger nominal flow (*)
Water side heat exchanger
nominal pressure drops (*)
P1 residual head (*)
P2 residual head (*)
ASP1 residual head (*)
ASP2 residual head (*)
Water tank content (ASP1/ASP2)
Amount of R410A refrigerant
Amount of Polyester oil
Electrical data
Absorbed power (*) (■)
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary power supply
Control power supply
Nominal current (■)
Maximum current (■)
Starting current (■)
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Width (a)
Height (b)
Depth (c)
Heat exchanger inlet/outlet connections
DS/RC100 inlet/outlet connections
(*) In the following conditions: Condenser inlet
air temperature 35°C; chilled water temperature
7°C; temperature differential at evaporator 5°C.
(***) Sound power level in dB(A) on the basis of
measurements taken in accordance with RS
6/C/005-2009. The noise data refers to the units
without the pump.
(■) Pumps excluded.
270
280
kW
70,3
79,5
2,60
2,68
3,27
3,28
3,25
3,47
3,75
4,02
5,56
6,02
6,42
6,97
dB(A)
85
85
2/3
2/2
1
1
n° x kW
2x2.13
2x2.13
m³/h
26000
26000
Pa
250
250
l
5,0
6,1
m³/h
12,1
13,6
kPa
42
37
kPa
134
129
kPa
254
247
kPa
131
125
kPa
251
243
l
250
250
270
280
kW
27,0
29,7
kW
1,1/2,2
1,1/2,2
V-ph-Hz
V-ph-Hz
V-ph-Hz
A
47,3
51,9
A
64,3
68,7
A
207
212
A
2,6/5,0
2,6/5,0
270
280
mm
1100
1100
mm
1920
1920
mm
3650
3650
2"
2"
Ø
2"
2"
Ø
Nota Bene:
The E.E.R. and C.O.P calculation does not
consider the absorption of the pumps.
The EER, ESEER and COP calculations
according to EN 14511 05/11 (250kPa residual)
refer to the versions without pumps.
The starting current reduces by 25% with the
SFS accessory
The machine decreases its noise below the
nominal value indicated in the table when the
outdoor air temperature is below 35°C and
condensation control is present.
If the INS accessory is present, the sound
power Lw decreases by 2 dB(A).
53
290
2100
2115
88,0
101,2
114,5
2,60
2,50
2,68
3,12
3,15
3,33
3,25
2,98
3,35
3,77
3,44
3,89
5,86
5,74
5,43
6,79
6,63
6,30
86
88
88
2/3
2/3
2/3
1
1
1
2x2.32
3x2.33
3x2.12
27000
39000
39000
250
250
250
6,1
6,9
8,4
15,1
17,4
19,6
45
47
42
119
110
106
248
238
232
117
108
103
246
236
229
250
250
450
See serial number plate
See compressor plate
290
2100
2115
33,8
40,5
42,7
1,5/3,0
1,5/3,0
1,5/3,0
400 – 3+N – 50
230 – 1+N – 50
24 – 1 – 50
54,0
67,6
77,6
72,7
85,4
91,2
262
313
319
3,5/6,0
3,5/6,0
3,5/6,0
290
2100
2115
1100
1100
1100
1920
1920
2320
3650
3650
4450
2"
2"
2"
2"
2"
2"
ENCLOSED DOCUMENTS
2130
2145
2160
126,0
143,0
161,0
2,68
2,64
2,67
3,24
3,32
3,26
3,48
3,30
3,46
4,00
3,80
3,99
5,42
5,32
5,37
6,24
6,13
6,19
88
89
89
2/2
2/3
2/2
1
1
1
3x2.16
4x2.25
4x2.25
39000
52000
52000
250
250
250
8,4
9,9
11,1
21,6
24,5
27,6
51
49
50
90
141
122
214
270
249
86
136
117
211
266
244
450
450
450
2130
2145
2160
47,0
54,2
60,4
1,5/3,0
2,2/4,0
2,2/4,0
84,5
95,0
106,6
100,2
116,1
127,1
327
368
382
3,5/6,0
5,0/8,1
5,0/8,1
2130
2145
2160
1100
1100
1100
2320
2320
2320
4450
4450
4450
2"
2"
2"
2"
2"
2"