WALMEC GENESI CARBONIO 360 HTE Clear Manual De Instrucciones página 17

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 55
e!
SPECIAL CONDITIONS FOR SAFE SPRAY GUN USE:
When using the spray gun, heat hazards may be due to:
- the use of hot compressed air;
- heated primer and finish product application.
In these situations, at most, the spray gun surface reaches the compressed air or primer and finish product temperatures.
In these conditions, pay ATTENTION to the following:
.
- the spray gun surface temperature should not exceed the burning limit of 43°C (UNI EN 1953 paragraph 5.4).
If this is the case, hand protection must be worn: (for example, heat resistant antistatic gloves);
- the spray gun surface temperature should never exceed 85°C, temperature sufficiently lower than the Minimum
Ignition Temperature (TMA) of solvents commonly used for bodywork, woodwork and industrial painting;
- in case of doubt, ask your dealer for information on the solvent TMA.
The list of construction materials used will be provided upon request.
FAILURES AND REMOVAL OF THEIR CAUSES
m contact
INTERMITTENT JET
hey emit.
ries due
ong and
PRODUCT LEAKS FROM
nd bolts
t!
mage to
ssages.
ISH
istruzioni WI34_18.indd 17
FAULT
UNEVEN JET
- Paint nozzle is loose
AIR BUBBLES IN THE
- Nozzle is worn out
PAINT TANK
- Nozzle and needle are clogged with dry paint
- Nozzle or needle is damaged
NOZZLE
- Needle pusher spring missing
DURING 1ST PHASE
- Rear air stuffing box worn
- Shutter worn
AIR LEAKS WITHOUT
- Valve scratched
PULLING THE LEVER
- OR valve worn
- Front air stuffing box loose
AIR LEAKS WHEN
- Front air stuffing box worn
LEVER IS PULLED
CAUSE
- Stuffing box needle loose
- Stuffing box needle worn
- Nozzle not fully tightened
- Nozzle cone ruined
- Air cap holes are dirty or damaged
- Central hole on cap is damaged or dirty
- Nozzle is dirty or damaged
17
SOLUTION
- Tighten the needle stuffing box nut
(for Genesi and Ego only)
- Replace the stuffing box needle
- Tighten nozzle
- Replace nozzle
- Clean carefully nozzle and cap
(with cleaning kit Ref. 90109/W)
if problem persists replace them.
- Firmly tighten the nozzle
- Replace nozzle
- Clean carefully needle and nozzle
- Replace needle and nozzle
- Insert the needle spring
- Replace rear air stuffing box
- Replace shutter
- Replace valve
- Replace OR valve
- Tighten the lever rod stuffing box
(for Genesi and Ego only)
- Replace the front air stuffing box
(for Genesi and Ego only)
- Replace the air valve (for Slim only)
09/01/18 14.18

Publicidad

Tabla de contenido
loading

Tabla de contenido