follow the instructions of the boat engine manufacturer on how to connect engine cooling
WARNING:
liquid to the heat exchanger.
• Fit the stub pipe (7) to the relief valve (5) using the hose clamp (6).
Fit the pipe so as to allow any possible water leak not to cause damage to parts of the boat.
• Open up hot water taps of the washbasins and start the water pump. This allows water to fill the water
heater and force air out of the water heater and pipes. Close taps as soon as air free water comes
out of the taps.
• Check that there are no leaks on pipe joints.
UNIT POWER SUPPLY (In models provided)
The unit is provided with power supply cable for AC current. See fig. 3 for the connection. Make sure the water
heater operating voltage is the same as that provided by AC network.
A double pole switch has to be included on the electric installation in order to turn on and off the unit, and a
fuse of suitable rating. The insulation between connection contacts of the AC network must be at least 3 mm.
The connections to AC network must be done following the National Specifications on electrical installations.
before carrying out the connection make sure the cables are not live.
WARNING:
WARNING:
in case the power supply cable is damaged, ensure it is replaced by a Quick service center.
In order to avoid accidents, the equipment has to be opened by authorized personnel only. If opened by
an unauthorized person, the warranty is considered void.
WARNING:
never activate the heating element unless the boiler is fully filled with water or the heating
element will be permanently damaged and the protection devices (double thermostat) will fail.
WARNING: never install the boiler in closed or not well ventilated rooms.
WARNING: never install the boiler in a room filled with gas or in potentially inflammable rooms.
THERMOSTAT ADJUSTMENT (in models provided)
The standard temperature value of the thermostat is 60°C.If you wish to change it, follow the instructions be-
low:
• shut down power supply.
• Remove the protection cover (12) in order to reach the thermostat.
• Adjust the thermostat knob with a screwdriver (fig. 4) and turn it to the required temperature.
• Replace the protection cover (12).
• Switch on power supply.
F
The thermostat sets the water temperature only with electric element operation.
BOILER BX15-100 - REV007A

USAGE - WARNING