FEATURES
PRODUCT SPECIFICATIONS
ENGINE
Engine Type .........................................GX390, 389cc, OHV
Fuel Volume ................................................................ 8 gal.
GENERATOR
Rated Voltage .....................................................120V/240V
Rated Amps ..................................................... 58.3A/29.1A
*Rated running watts determined by PGMA Standard G200
KNOW YOUR GENERATOR
See Figure 2.
The safe use of this product requires an understanding of the
information on the product and in this operator's manual as
well as a knowledge of the project you are attempting. Before
use of this product, familiarize yourself with all operating
features and safety rules.
AC CIRCUIT BREAKER
The circuit breaker is provided to protect the generator
against electrical overload. The circuit breaker may be reset
by pressing the circuit breaker reset button.
AIR FILTER
The air filter helps to limit the amount of dirt and dust drawn
into the unit during operation.
ANALOG HOUR METER
The analog hour meter operates whenever the engine is
running and keeps track of how many hours the unit has
been used.
CHOKE
The choke is used when starting the engine.
FUEL TANK
The fuel tank has a capacity of 8 gallons.
FUEL VALVE
Fuel flow from the fuel tank to the engine is turned on and
off using the fuel valve.
Rated Running Watts* ............................................7,000 W
Rated Starting Watts ..............................................8,750 W
Rated Frequency ........................................................60 Hz
GROUND TERMINAL
The ground terminal is used to assist in properly grounding
the generator to help protect against electrical shock.
Consult with a qualified local electrician for grounding
requirements in your area.
LOW OIL SHUT DOWN PROTECTOR
The low oil sensor causes the engine to stop if the level of
lubricant in the crankcase is insufficient.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the
generator when necessary.
OIL DRAIN PLUG
When changing the engine lubricant, unscrew and remove
the oil drain plug to allow old engine lubricant to be drained.
RECEPTACLES
The following single phase, 60 Hz outlets on the control panel
can be used for operating appropriate equipment, electrical
lighting, tools, and motor loads: two 120 Volt AC duplex GFCI
20 Amp receptacles and one 240 Volt AC, 30 Amp receptacle.
RECOIL STARTER GRIP
The recoil starter grip is used to start the generator's engine.
STOP SWITCH
To turn the engine off, press and hold the STOP switch until
the engine stops.