5.3.3 - Memory deletion

Each new programme replaces the previous settings. It is usually unnecessary
to "delete all" the parameters". If required, the memory can be totally deleted by
01. Switch the control unit off and wait until all the LEDs have gone off (remove fuse F1 if necessary)
02. Press at the same time and hold down P1 and P2 on the board and turn the control unit on
03. Release P1 and P2 after exactly 3 seconds
If the memory was deleted correctly, all the Leds will switch off for 1 second; if the leds continue to flash, the entire memory deletion procedure must be
repeated.

5.3.4 - Example of level one programming

The following examples show how to activate or deactivate a level one function,
01. Access the level one programming mode by pressing P1 and P2, and keeping them pressed down for at least 3 seconds
02. Press P1 once to move the flashing Led to the Led 2 (the flashes will be short)
03. Activate the "Condominium" function by pressing P2 (the flashes will be longer)
04. Press P3 once in order to activate part two (the P3 LED will switch on)
05. Press P1 once to move the flashing Led to the Led 2 (the flashes will be short)
06. Activate the "Electric lock" output by pressing P2 (the flashes will be longer)
07. Exit programming (with memorisation) by pressing P1 and then immediately P2, holding them both down
for at least 3 seconds

5.3.5 - Example of level two programming

This example shows how to modify a level two parameter, for example, how to
01. Access the level one programming mode by pressing P1 and P2 for at least 3 seconds
02. Press P1 three times to move the flashing Led to the Led 4
03. Access level two by pressing P2 for at least 3 seconds
04. Press P2 three times until Led 5 switches on
05. Return to level one by pressing P1
06. Exit programming (with memorisation) by pressing P1 and then immediately P2, holding them both down
for at least 3 seconds
TABLE C1 - Delete memory
Example of level one programming:
activate the "Condominium" function and "Electric lock" output
Example of level two programming: modifying "current sensitivity"
performing this simple operation: WARNING – As all the functions return to
their pre-set values after the memory is deleted, a new search for the
limit switches must be carried out.
the "Condominium" function, for example, and prepare the "Gate Open Indica-
tor" output in order to activate the electric lock.
modify current sensitivity intil "level 5".
P1
P2
and
P1
P2
3s
P1
P2
P1
2
x1
P2
P3
2
P1
P2
P1
P2
P1
P2
P1
4
x3
P2
P2
x3
P1
P1
P2
English – 7
3s
3s
3s
3s
5
3s

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Poa1

Tabla de contenido