with reference to the terminals C and D of the inverter.
The inverters of the AVy series are supplied with a command for the external braking units;
all BUy-... have to be configured as Slave. The terminals 26 and 27 of the inverter are con-
nected to the terminals 7 and 8 (SIN) of the first BUy, which, on its turn, is connected to the
following BUy with its terminals 5 and 6. The terminals 9 and 10 (SOUT) are short-circuited.
See the following example.
Figure 3.4.2: Parallel connection of several units (Slave), to the Master Drive AVy