Operating The Generator; Basic Notes On Operation - Dometic TEC29 Instrucciones De Uso

Ocultar thumbs Ver también para TEC29:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 78

Operating the generator

8
Operating the generator
NOTICE!
A
Do not run the generator over 70% of the maximum constant output
for the first 50 operating hours (run-in phase).
NOTE
I
By doing this you can prolong the service life of the generator and
optimise its output:
run the generator at a maximum of approx. 75% of the maximum
continuous load after the run-in phase.
8.1

Basic notes on operation

CAUTION! Beware of injury
!
Do not insert your fingers or objects into the air nozzles or the in-
take grille.
Please note the following basic information:
 Always check the oil level before use ("Checking the oil level" on
page 44).
 TEC29LPG only: Check there are no leaks from the gas supply using a
leak detection spray before every use.
 Even small overloads in the long-run will cause the thermo switch
(TEC29) or the fuses (TEC29LPG) to trigger.
 Leave the generator running for a few minutes after use without any con-
sumers before stopping it.
 Abrupt braking, accelerating and driving round bends in the vehicle can
cause problems in the generator's pump system and lead to unwanted
shutdown.
 If you are not using your generator for a longer period of time, start it up
at least every 30 days and leave it running for 15 minutes or more.
40
TEC29, TEC29LPG
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Tec29lpg

Tabla de contenido