ter will flow out from the tank and damage the
BG
objects nearby. Moreover, because of the dam-
age, it might result in fire or an electric shock
CZ
DE
► FIG. 13
Make the filter more endurable. When off for a
DK
long time, seal the filter in a plastic bag.
EE
► FIG. 14
Do not use the unit near water. The unit might
ES
be damaged when soaked in water, so as to re-
sult in fire or electric shock.
FI
► FIG. 15
FR
Use
the
standard
220-240V/~50Hz. Otherwise it might result in
GB
fire or electric shock.
HR
► FIG. 16
Do not damage the wire. Do not put anything
HU
heavy on the wire or heat or pull the wire. Oth-
erwise it might result in fire of an electric shock.
IT
LT
► FIG. 17
Clean the dirt on the plug and fix it tightly. If the
LV
plug is not fixed tightly, it might cause an electric
shock.
NL
► FIG. 18
NO
Do not regard the plug as a switch. Otherwise it
might result in fire or an electric shock.
PL
►►
5. NOTICES ABOUT UNIT OPERA-
►
RO
TION
RU
► When moving the unit, do not tilt over 45°to
avoid any damaging of the compressor.
SE
► The unit should be operated between 5°~32°.
► When dehumidifying, because of the heat re-
SI
sulted from the running compressor, the indoor
temperature will rise by 1°~3°. Such a reaction
SK
should be considered as normal.
UA
► When indoor temperature is below 10°, and
the ambient absolute humidity is quite low, it is
SE
unnecessary to use the machine.
► Air inlet and air outlet should be at least 10cm
SI
away from the wall.
► Try to keep the room closed to enhance the
SK
dehumidification effect.
► Too much dirt on the filter affects dehumidi-
fication, may even result in malfunctioning of it,
thus it should be cleaned at least once a month.
If there is a great amount of powder in the air,
electric
source
of
the filter must be cleaned once a week, or even
every day. Pull the front panel out and clean the
filter. If necessary, you may slightly knock all
over the filter, use a vacuum cleaner to remove
bigger pieces of dirt or even wash the filter in
warm clean water (≤40% with some neutral de-
tergents) and then dry it.
►►
6. TROUBLE-SHOOTING
►
UNIT DOES NOT WORK
► Analysis
1.Power cut
2.Switch off
3.Unplugged
4.Fuse melted
5.Tank full
► Solution
1.Power on
2.Switch on
3.Plug on
4.Exchange fuse
5.Empty the tank and replace it
DEHUMIDIFIES IN INADEQUATELY
► Analysis
1.Filter choked by dirt
2.Some barrier
in air inlet or outlet
3.Door or windows open
4.Refrigerant leakage
► Solution
1.Clean the filter
2.Remove the barrier
3.Close the door and windows and
seclude from the sunshine
4.Contact the manufacturer or seller
WATER LEAKAGE
► Analysis
1.The unit is inclined
2.Drainer choked
► Solution
1.Adjust the unit to be stable
2.Pull out the panel and remove the barrier
STRANGE NOISE
► Analysis
1. Until instable
2. Filter choked