2. Remove power from circuit.
3. Measure capacitance by connecting test leads across the capacitor.
The meter will auto-range to display the measurement in the most
appropriate range.
Black lead Red lead
TEMPERATURE
1. Insert K-type thermocouple (with adapter) into the V
COM
jacks (observe polarity markings on thermocouple
4
and meter), and rotate function selector switch
Temperature
NOTE: The meter defaults to Fahrenheit scale in this mode. To enter
Celsius scale, press the "SEL" button
appropriate icon (either °F or °C ) appears on the display.
NOTE: The meter may be set to default to the Celsius scale by
powering-ON the meter from the OFF position with the Data Hold
& Backlight button
Fahrenheit scale repeat the power-ON sequence.
2. To measure temperature, make contact between the
thermocouple tip and the object being measured. When
thermocouple tip and object are in thermal equilibrium, the
measurement on the display will stabilize. The meter will auto-
range to display the measurement in the most appropriate range.
Remove thermocouple before switching meter to other
measurement functions.
The thermocouple included with the original purchase
is suitable for temperatures below 356°F / 180°C only.
To measure higher temperatures, a K-type thermocouple
with the appropriate measurement range should be used.
14
OPERATING INSTRUCTIONS
setting.
depressed. To re-set the default to the
6
K-Type Thermocouple
(with adapter)
RED
BLACK
Adapter
once. Ensure that the
9
Thermocouple
and
5
to the