Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
FREQUENCY (AUTO-RANGING)
9.999Hz
99.99Hz
999.9Hz
9.999kHz
99.99kHz
500.00kHz
Sensitivity: > 8V RMS
Maximum Input: 600V DC or 600V AC RMS

DUTY CYCLE

1% to 99.9%
Pulse width: 0.1 – 100ms
Frequency width: 5Hz to 10kHz
Sensitivity: >8V RMS
Maximum Input: 600V DC or 600V AC RMS
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V AC RMS or 600V DC
• Diode Test: Max. 1.5mA, open circuit voltage ~3.0V DC
• Continuity Check: Audible signal <50Ω, test current <0.35mA
• Sampling Frequency: 3 samples per second
• Low Impedence (Low Z): Input impedence >3k
• Auto Power off: After ~30 minutes of inactivity
• Overload: "OL" indicated on display, overload protection
1000V in Voltage setting, 600V RMS in all other settings
• Polarity: "-" on display indicates negative polarity
• Display: 3-5/6 digit, 6000 Count LCD
To ensure safe operation and service of the meter, follow these
instructions. Failure to observe these warnings can result in
severe injury or death.
• Before each use verify meter operation by measuring a known
voltage or current.
• Never use the meter on a circuit with voltages that exceed the
category based rating of this meter.
• Do not use the meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Use only with CAT IV rated test leads.
4
ELECTRICAL SPECIFICATIONS
0.001Hz
0.01Hz
0.1Hz
1Hz
10Hz
100Hz
0.1%
Max input 600V RMS
WARNINGS
±(1.0% + 5 digits)
±(1.2% + 2 digits)

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido