TURNING
THE BOILER OFF (fig. 1)
To turn the boiler off place the selector
knob on the OFF position.
If the boiler is not going to be used for
a lengthy period it is advised to turn off
the electricity supply, close the gas tap,
and if the temperatures foreseen are
low, empty the boiler and the hydraulic
system to avoid breakage in the tubes
due to the freezing of the water.
FAULT FINDING
– Ignition lock-out (fig. 3)
If the burners do not ignite, the red led
will light-up (
).
To attempt a boiler restart, rotate the
selector knob to position (
se it immediately, placing it in the sum-
mer (
) or winter (
tion.
If the boiler lock-out re-occurs, contact
an authorised Service Centre.
– Insufficient water pressure (fig. 4)
If the red "0.5" bar led starts flashing,
the boiler will not function.
To restart operation, rotate the charge
valve anticlockwise until the green "1
bar" led lights up.
If all the leds are off, call the local autho-
rised Service Centre for technical assi-
stance
– Safety stat trip (fig. 5)
If the safety thermostat trips, the red
"35°C" led will start flashing. In order to
attempt a boiler restar t, rotate the
selector knob to position (
se immediately, returning it to the sum-
mer (
) or winter (
If the boiler lock-out occurs again, call
local authorised Service Centre for
technical assistance.
102
GAS CONVERSION
Should it be necessar y to conver t the
appliance to a different gas from the one for
which the boiler has been equipped, approa-
ch the technical staff.
CLEANING AND MAINTENANCE
At the end of each heating season, it is
essential to have the boiler thoroughly
) and relea-
)operation posi-
) and relea-
) position.
RED LED
SPIA ROSSA
FLASHING RED LED
SPIA ROSSA INTERMITTENTE
IN CONDIZIONE DI SICUREZZA
IN SAFETY CONDITION
GREEN LED IN OPERATING
SPIA VERDE IN CONDIZIONE
DI FUNZIONAMENTO
OPEN
APRE
FLASHING RED LED
SPIA ROSSA INTERMITTENTE
checked and cleaned out.
Preventive maintenance and checking of
the efficient operation of the equipment
and safety devices must be carried out
exclusively by the authorized technical
staff. The boiler is supplied with an elec-
tric cable. Should this require replace-
ment, contact exclusively with the autho-
rized technical staff.
CONDITION
Fig. 3
Fig. 4