Sime Planet AquaQuick Serie Manual Del Usuario página 92

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.8.2
Separate-pipes
roof outlet
The accessories to be used for this type of
installation and some of the connecting
systems that may be adopted are illustra-
ted in fig. 10.
There is the possibility of doubling the air-
intake and smoke-outlet pipes and then brin-
ging them back together again so as to
obtain a concentric discharge by using the
doubler fitting (7 fig. 10).
For this type of discharge the sum of the
maximum rectilinear development allowed
for the pipes must not exceed 7,00 mm
H
O ("25" version) and 11,00 mm H
2
("30" version).
When calculating the lengths of pipe, take
into account the parameters given in the
Table 2.
2.9
FORCED OUTLET
(B
type)
22
The "PLANET AQUAQUICK 25 BF" version
can also be installed as a B
tus by assembling the stub pipe inlet/outlet
kit code 8089950.
The kit comes with a sector diaphgram,
instruction sheet and a label with the room
aeration warnings to be attached to the boi-
ler casing.
The sector diaphram must be used accor-
ding to the maximum load loss allowed by
the duct, as indicated in fig. 8/a. The com-
plete range of fittings required to carry out
the installation is given in fig. 11.
88
O
2
type appara-
22
KEY
1 Air-smokes flow splitting unit
with take-off points code 8093000
2a 90° elbow MF code 8077404
2b Isolated 90° elbow MF code 8077408
3a Extension L. 1000 code 8077303
3b Isolated extension L. 1000 code 8077306
4 Outlet terminal code 8089501
5 Int.-est. ring lit code 8091500
6 Intake terminal code 8089500
7 45° elbow MF code 8077406
8 Condensation outlet L. 135 code 8092800
9 Locking junction (n. 5) code 8092700
KEY
1
Air-smokes flow splitting unit
with take-off points code 8093000
2 a 90° elbow MF code 8077404
2 b Isolated 90° elbow MF code 8077408
3 a Extension L. 1000 code 8077303
3 b Isolated extension L. 1000 code 8077306
4
Int.-est. ring kit code 8091500
5
Intake terminal code 8089500
6
Locking junction (n. 5) code 8092700
7
Doubler fitting code 8091400
8
Tile with articulated joint code 8091300
9
Roof outlet terminal L. 1390code 8091201
10
45° elbow MF code 8077406
11
Condensation outlet L. 135 code 8092800
12
Tee condensation outlet code 8093300
Fig. 9
Fig. 10

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Planet aquaquick 25 bfPlanet aquaquick 30 bf

Tabla de contenido