Descargar Imprimir esta página

After Usage; Care And Maintenance - MESTO FERROX PLUS 3565P Instrucciones De Uso

Ocultar thumbs Ver también para FERROX PLUS 3565P:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
GB
IRL

After usage

Observe the instructions in the section entitled "Safety".
1. Pull up the red button on the safety valve [12] until all excess pressure is released from
the tank. (
2. Lock the pump handle in place [13].
3. Unscrew the pump [2] from the tank [1].
4. In the case of plant protection products dilute the remaining quantity twice in a row with
1/2 liter of water each time and spray the resulting liquid onto the treated area.
Collect and dispose of the residual liquid according to all applicable laws, requirements
and regulations. Observe the instructions of the spray product manufacturer!
5. Empty and rinse the device with clear water.
6. Wipe off the device with a moist cloth.
7. For drying and storing the device, keep the tank and pump separate in a dry place pro-
tected from sunlight and freezing temperatures.
Clean the protective equipment and yourself every time after usage.

Care and maintenance

Observe the instructions in the section entitled "Safety".
After using the device 50 times or at least once a year:
Disassemble the pump [2] and grease the diaphragm [20].
Clean the nozzle [21] under running water. If required use a needle.
under running water.
Grease the O-rings [19] and [24]
Observe the legal requirements of your country for accident prevention and check
the device in regular intervals. If there are no special rules, we recommend you
have the device examined externally by a competent professional every 2 years
and subject it to an internal inspection every 5 years. We would be happy to provi-
de you with an inspection schedule in German or English.
Faults
pouch [3],
Fault
No pressure builds up
in the device
AUS
.
.
Cause
The pump is not screwed on
tightly.
O-ring [19] on the pump is
faulty.
Diaphragm [20] is defective. Replace the diaphragm.
USA
NZ
.
.
Remedy
Screw the pump on tightly.
Replace the O-ring.
17
CDN
IND
.
.
.

Publicidad

loading

Este manual también es adecuado para:

Ferrox plus 3585pInox plus 3595pInox plus 3615p