PRODUCTION
DISPLAY
HOVERS AROUND
100
N.B.:
In "SPRING MODE" the unit works in the same way, the only difference being the reading given by the production
display, which hovers around 85 instead of 100 (normal mode value).
5.2 Other Indications
STANDBY
The "STANDBY light comes on when the unit is getting ready to start producing chlorine and stays on for about 30
seconds at the start of the cycle or when the cell is not producing.
FLOW
I there is a problem with flow, or gas in the cell, the FLOW indicator lights up, in which case you should check the
pump, the filtration system lines and the connection between the gas detection wire and the cell.
12
LED 1
LED 2
GREEN
GREEN
GREEN
RED
RED
RED
MEANING / CORRECTIVE ACTION IF REQUIRED
Normal Operation
1. Water salinity too low. Check salinity and add 1 kg of salt
per m
of water in the pool.
3
2. The cell is encrusted with scale and needs cleaning.
3. Water temperature too low (below 20ºC). Switch to
"SPRING MODE" (button on the front face of the unit).
1. Water salinity too low. Add salt to the pool
(1 kg per m
of water).
3
2. The cell is encrusted with scale and needs cleaning.
3. Water temperature too low (below 20ºC). Switch to
"SPRING MODE" (button on the front face of the unit).
4. Check to make sure there is no air in the cell. If there is,
the luminous Flow dot lights up (see "other indications").