3. INSTALLATION
The unit should be installed by a professional and in accordance with current accepted practices (IEC Standard
•
364-7-702 and NFC 1500 Section 702).
The power supply should include electrical protection and isolating gear in accordance with the regulations in
•
force.
See General Installation Diagram, Appendix 1
•
First select a place inside the plant room where you can fix the switch cupboard at a height at which it can be
•
accessed and read easily.
Connect the control unit in parallel with the filter circuit pump such that the unit only starts when the pump is in
•
operation.
IMPORTANT: The cell is connected to the hydraulic circuit after all the other items of equipment (pump, filter,
•
heating, blower, etc.), just before the hydraulic circuit return into the pool.
The cell must be fixed horizontally at a level just slightly above the level of the filter.
•
Fix cell in accordance with the direction of the arrow located on the body of the cell; this shows the direction in
•
which the water flows in the cell.
You must position the cell such that it can be removed easily for cleaning purposes, should that become necessary.
•
Connect the electrode power input to the switch cupboard.
•
MPS models: Connect the two plugs to the connectors on the cell.
•
Connect the safety device to the terminal provided for this purpose on the cell.
•
NOTE: One of the adapters of the cell is made with a bolt. Install this Adaptor in between the cell housing (opposite
side to the threaded side of the cell housing) and pipe. The bolt is to make a connection to an independent earth –
Refer to installation drawing
To connect blanket switch :
•
>Push "banana" plugs into the bottom of the
black-black "banana" sockets OR
>Push wires into the holes at sides of the black-black terminals and screw down to fasten
NOTE: Plugs or wires can be connected into either of the black terminals
9