INDICATORS
3
2
1
0
A
B
C
Indication Description
0
E rror mode, the charger suspends the charging / voltage maintenance.
See further description below.
1
Soft start.
2
Bulk charging, maximum voltage.
3
Absorption charging, voltage limited to chosen voltage.
4
Pulse maintenance charging
5
Supply, fixed output voltage, no counter voltage requirement.
6
Recond
A
Charging without temperature compensation
B
STANDBY
C
Mode "NORMAL" (14.4V)
D
Mode "SUPPLY" (13.6V)
E
Mode "RECOND" (15.7V, 3A 0.5–4h)
Error mode
The charger enters error mode before start in the following situations:
• The battery is connected with poles reversed to the charger's terminals.
• The terminals on the charger are short-circuited.
Error mode before start is reset by removing the error situation. The charger restarts in
the latest selected mode.
The charger enters steady error mode in the following situations:
• The charger's analysis function has interrupted charging.
• The charger is overloaded in Supply mode.
• The charger has been in start mode longer than maximum time.
Steady error mode is acknowledged/reset by pressing the "MODE" button. The charger
restarts in the latest selected mode.
4
5
6
D
E
US • 11