DIP
DEFAULT
1
OFF
2
OFF
3
OFF
4
OFF
5
OFF
6
OFF
7
OFF
8
OFF
9
OFF
10
OFF
*= Configurazione di default
*= Default configuration
*= Configuration par défaut
*= Default-Konfiguration
*= Configuración por defecto
*= Конфигурация по умолчанию
Posizione/Position/Position/Posiciòn/ расположение
Dip 1
Dip 2
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
DEFAULT
5
6
7
8
9 10
ON
I
4
MPIANTO A
4
PIPE UNITS
I
4
NSTALLATION À
Termostatazione con Fan
Thermal power station with Fan
Termostatisation avec ventilateur
Ventilazione contemporanea delle valvole
Simultaneous ventilation of valves
Ventilation simultanée des vannes
T3 Inverno ed Estate
T3 Winter and Summer
T3 Hiver et été
Motore ECM
ECM Motor
Moteur ECM
Pulsante IAQ/Resistenza ABILITATO
Button IAQ/Resistance ENABLED
Bouton IAQ/Résistance ACTIVÉ
Gestione Resistenze
Resistance-coils Management
Gestion des résistances
Gestione Resistenze con T2
Resistance-coils with T2
Gestions des résistance avec T2
CA = Estate/Inverno remoto
CA = Remote Summer/Winter
CA = Été/hiver à distance
--
DEFAULT
Dip 3
Dip 4
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
IMPOSTAZIONE
DIP DI
CONFIGURAZIONE
Posizione / Position / Position
TUBI
TUBES
T2 come Change-Over CH (resistenza II° gradino)
T2 as CH Change-Over (resistance phase II)
T2 comme changement de marche CH (résistance II° échelon)
IMPOSTAZIONE
MOTORE ECM
Tramite il blocco dip "D2"
è
possibile
le tensioni in uscita del
motore
ECM
recchiatura
tabella :
Velocità/Speed/vitesse/Geschwindigkeit/velocidad/скорость
Vel.1
7 V.
4 V.
5 V.
2 V.
6 V.
2,5 V.
3,5 V.
1 V.
5
SETTING THE
CONFIGURATION
DIPSWITCHES
OFF
I
2
MPIANTO A
TUBI
2
PIPE UNITS
I
2
NSTALLATION À
TUBES
Termostatazione con valvole
Thermal power station with valves
Termostatisation avec vannes
Ventilazione continua
Continuous ventilation
Ventilation continue
T3 solo Inverno
T3 only Winter
T3 seulement hiver
Motore Asincrono
Asynchronous Motor
Moteur asynchrone
Pulsante IAQ/Resistenza DISABILITATO
Button IAQ/Resistance DISABLED
Bouton IAQ/Résistance DESACTIVÉ
IAQ
CA = ON/OFF remoto
CA = Remote ON/OFF
CA = MARCHE/ARRÊT à distance
--
ECM MOTOR
SETTING
The "D2" set dip user to
impostare
set the output voltage
of the ECM motor of the
dell'appa-
equipment in accordance
secondo
la
with the table:
Vel. 2
8,5 V
5,5 V.
6,5 V.
4 V.
7,5 V.
4,5 V.
5,5 V.
3,5 V.
Vel. 3
10 V.
7 V.
8 V.
6 V.
9 V.
6,5 V.
7,5 V.
6 V.