4.
Safty cable
Pipe
6.
7.
• Since the camera unit and dome cover will be in a suspended state from the base by the
drop-prevention wire, the camera unit and dome cover will also move when mounting
the base to the pipe. Facing the camera lens to the dome-cover side at this time may
cause scratching of the lens. Make sure the dome cover and camera unit are facing
opposite sides.
• When screwing in the pipe into the conduit hole, do not screw in more than 12mm(
to prevent damage to the pipe interior.
5.
Seal tape
15
12mm(
/
")
32
or less
Not
Supplied
CAUTION
4.
Connecting the safety cable
To prevent dropping, connect the unit to
a sturdy location (ceiling slab or chan-
nel) and safety cable.
CAUTION
• For the used safety cable, pay particu-
lar caution to the length, strength, pull,
material (insulation), etc.
• Always use the screws (M4 X 8mm)
mounted on the unit.
5.
Wrap seal tape
Wrap the screw section of the pipe with
at least 2 rolls of seal tape.
Wrap the seal tape where the pipe-hole
screws and pipe screws meet.
6.
Mount the base to the pipe
Screw in the base to the pipe by turning
it clockwise.
(Conduit hole: 19.1mm (
When the Dome camera cannot be in-
stalled to the Ceiling (
When installing the Dome camera to the
electrical box (
7.
Fix the base to the ceiling
Securely tighten using screws suitable
for the mounting holes (ø4.4mm(
CAUTION
Check to make sure there is no gap be-
tween the ceiling and base.
3
/
"))
4
page 16)
page 17)
11
/
")).
64
15
/
")
32
E-11