Axis Communications Q1604-E Manual De Instalación página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 95
2
DC output
3
Digital Input
4
Digital
Output
Power Connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage
(SELV) compliant limited power source (LPS) with either a rated output
power limited to ≤100 W or a rated output current limited to ≤5 A.
Audio Connector
3.5 mm audio
connectors (stereo)
1 Tip
Audio Input
Microphone/Line in
Audio Output
Line out (mono)
AXIS Q1604-E Network Camera
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate.
Connected to pin 1 when activated, floating
(unconnected) when deactivated. If used
with an inductive load, e.g. a relay, a diode
must be connected in parallel with the load,
for protection against voltage transients.
3
2
1
2 Ring
15
3.3 V DC
Max load = 50 mA
0 to max 40 V DC
0 to max 40 V DC, open
drain, 100 mA
3 Sleeve
Ground
Ground

Publicidad

Tabla de contenido
loading

Tabla de contenido