6) Secure the icemaker to the storage bin, by using the two mounting
brackets and two bolts provided.
7) Seal the seam between the icemaker and the storage bin with food
grade sealant.
8) Refit the side panels in their correct position.
9) Adjust the four legs on the bottom (adjustable from 0 to 25.4 mm)
to have the icemaker perfectly horizontal. Use the spirit level.
6. ELECTRICAL CONNECTIONS
This icemaker requires an earth that meets the national and local electrical code requirements.
To prevent possible severe electrical shock to individuals or extensive damage to the unit, install a proper earth wire to the icemaker.
Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.
* This appliance requires a separate 220 - 240VAC, 17A (FM-1000, 600) / 12A (FM-750, 480) / 8A (FM-300) / 7A (FM-170)
supply. The electrical supply must be protected by a suitable circuit breaker.
* Usually an electrical permit and services of a licensed electrician are required.
[FM-1000, 600]
* If the supply cord and/or the plug should need to be replaced, it should only be done by a qualified service engineer.
* The fixed wiring must incorporate a means for disconnection from the supply having a contact separation of at least 3 mm in all
poles.
[FM-750, 480, 300, 170]
* If the supply cord is damaged, it must be replaced by a replacement cord available from Hoshizaki Parts/Service Centres.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this appliance may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured Green-and-Yellow must be connected to the terminal in the plug which is marked with the letter
E or by the symbol
terminal which is marked with the letter N or coloured Black. The wire which is coloured Brown must be connected to the
terminal which is marked with the letter L or coloured Red.
* Should the socket outlets in the installation site not be suitable for the plug supplied with your product, the plug must be
removed (cut off if it is moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the power supply cord, it must be disposed of. There should be no attempt to
reuse it. Inserting such a plug into a socket elsewhere presents a serious risk of electrical shock.
* The non-rewirable plug must never be used without a fuse cover being fitted.
The correct replacement for the detachable fuse cover is identifiable from the manufacturer's reference number stamped on
the plug.
Supply of replacement fuse covers can be obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 12A and approved to BS 1362.
THIS APPLIANCE MUST BE EARTHED
or coloured Green or Green-and-Yellow. The wire which is coloured Blue must be connected to the
Bolt
Mounting
Bracket
WARNING
4
Icemaker
Bin
Adjust legs