HE360 HUMIDIFIER AND INSTALLATION KIT
Controlling Your Humidity Settings
Your H8908 Humidistat controls your humidifier.
• Choose the humidity control setting using the combination of relative humidity/outdoor temperature setting
scale on your humidity control dial.
• Match the dial setting to the outdoor temperature to optimize the humidity level while reducing the moisture
condensation on your windows. See Table 2 to adjust the humidity control to the recommended setting.
NOTE: As the outside temperature drops, a lower humidity setting is recommended to accommodate
dewpoint effects. These settings should reduce the accumulation of moisture and ice on windows
and other areas of the home.
• Adjust the humidity control setting to adjust for indoor activities such as cooking, showering and clothes
drying, which can cause excessive levels of humidity that can accumulate moisture on your windows.
NOTE: If these activities persist for more than a few hours, set the humidity control to the lowest setting to
turn off the humidifier. If the condition does not improve, ventilate your home to remove the
moisture.
69-2631ES—05
Table 2. Setting Your Humidistat.
When Outside
Temperature is:
-20°F (-29°C)
-10°F (-23°C)
0°F (-18°C)
+10°F (-12°C)
+20°F (-7°C)
Above 20°F (-7°C)
Use This Control
Setting:
15
20
25
30
35
40
14