Adjusting The Fc2 Closing Limit Stop - SOMFY IXENGO L Manual De Instalación

Ocultar thumbs Ver también para IXENGO L:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Adjusting the Fc2 opening limit stop
[1] Slacken the mounting screw K on the limit stop.
[2] Perform an opening cycle to check precisely where the limit stop
takes effect.
[3] The motor stops when the edge of the end limit and the edge of
the magnet are aligned (i.e. when the magnet conceals the end limit).
[4] If the gate section does not open completely, slightly move the limit
stop towards the motor drive unit's body.
[5] If the gate section hits the limit stop on the ground when opening,
and the motor drive unit reverses direction, then move the limit stop
slightly towards the head cap L.
[6] After correctly defining the limit stop's position, tighten down screw K.
Important: to avoid breaking the limit stop wire, tighten down screw K while keeping the wire N taught.
Note: When programming the electronic controller, always
anticipate when the limit stops will take action. To properly
press against the limit stops on the ground, the motor drive
unit continues its movement for 1 or 2 cm (some 100 ms).
Copyright © 2008 Somfy SAS. All rights reserved.