Omron E5AR-T Manual De Instrucciones página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
1. Input Allocation List
Set
Input type
value
name
(˚C)
0
-
Pt100(1)
1
- 150.00 - 150.00
2
-
K(1)
3
-
4
-
J(1)
5
-
6
-
T
7
E
0.0 - 600.0
8
-
L
9
U
-
10
N
-
11
R
0.0 - 1700.0
12
S
0.0 - 1700.0
13
B
14
W
One of the following ranges is
15
displayed by scaling.
16
- 19999 - 99999
17
1 - 5V
- 1999.9 - 9999.9
18
0 - 5V
- 199.99 - 999.99
19
0 - 10V
- 19.999 - 99.999
- 1.9999 - 9.9999
The default settings are Set Value:
3. Alarm type list
Alarm type
Positive alarm value (X) Negative alarm value (X)
0 No alarm function
ON
1
Upper/lower limit
OFF
ON
2
Upper limit
OFF
ON
Lower limit
3
OFF
Upper/lower limit
ON
4
range
OFF
Upper/lower limit
ON
5
with standby
OFF
sequence
Upper limit with
ON
6
standby sequence
OFF
Lower limit with
ON
7
standby sequence
OFF
Absolute-value
ON
8
upper-limit
OFF
Absolute-value
ON
9
OFF
lower-limit
Absolute-value
ON
upper-limit with
10
OFF
standby sequence
Absolute-value
ON
11
lower-limit with
OFF
standby sequence
1:Upper and lower limits can be set for parameters 1, 4 and 5 to provide for
different types of alarm. These are indicated by the letter "L" and "H".
9
Input range
Input type
switch
(˚F)
- 300.0 - 1500.0
Set to TC.PT
- 199.99 - 300.00
-
0.0 - 900.0
- 100.0 - 1500.0
TC.PT
0.0 - 750.0
- 300.0 - 700.0
IN1
TYPE
0.0 - 1100.0
- 100.0 - 1500.0
ANALOG
- 300.0 - 700.0
-
0.0 - 3000.0
0.0 - 3000.0
0.0 - 4100.0
Set to ANALOG
TC.PT
IN1
TYPE
ANALOG
Type SW:
C
Alarm output function
Output OFF
L
H
Always ON
SP
X
ON
OFF
SP
X
ON
OFF
SP
L
H
Always OFF
SP
L
H
Always OFF
SP
X
ON
OFF
SP
X
ON
OFF
SP
X
ON
OFF
0
X
ON
OFF
0
X
ON
OFF
0
X
ON
OFF
0
. Output Type List
Output type
Set
Name
value
Pulse
0
output
Linear
1
output
The def
4. Auto tuning
The timing for generating the limit cycle
varies depending on whether or not the auto
tuning start deviation (DV) is below 10% FS.
The action of auto tuning PV is as follows:
Deviation ≥ 10% FS
Present
value
Set
value
X
AT starts
SP
Deviation < 10% FS
Present
value
X
Set
SP
value
10% FS
deviation
AT start
X
SP
However, PV action is as follows during
X
ON/OFF control, heating/cooling control,
SP
and position proportional control (floating).
X
0
Present
X
value
0
Set
X
value
0
X
0
AT start
Input type switch (bottom)
Linear current
output type
Set
Output range
value
0
1
4
Limit cycle
Change in manipulation
value of 40%
10% FS
deviation
Time
AT ends
Limit cycle
Change in manipulation
value of 40%
Time
AT end
Limit cycle
Change in manipulated
variable of 100%
Time
AT end

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

E5er-t

Tabla de contenido