Pcb Parameters - klover DEA ECO8 Instalación Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PCB PARAMETERS

THE PARAMETERS STORED ON THE PCB ARE ESSENTAL FOR THE CORRECT OPERATION OF THE
STOVE.
THE PARAMETERS SHOWN BELOW ARE STORED DURING THE STOVE TESTING PHASE DIRECTLY
AT THE FACTORY.
THESE PARAMETERS STEM FROM ACCURATE TESTS WITH VARIOUS TYPES OF PELLETS AND
MUST NOT BE MODIFIED WITHOUT PRIOR AUTHORISATION FROM KLOVER srl, IN ORER TO AVOID
JEOPARDISING THE STOVE'S OPERATION.
THE COMPANY SHALL NOT BE HELD LIABLE FOR ANY DAMAGES CAUSED BY INCORRECT
PARAMETER ENTRY.
"Factory calibrations" (Menu M8 – 1) (Firmware H02_250117)
Parameter
Description
Pr01
Ignition cycle maximum time
Pr02
Start time
Time interval between the two brazier
Pr03
cleaning operations
Screw feed gearmotor ON time in ignition
Pr04
phase
Screw feed gearmotor ON time in start
Pr05
phase
Screw feed gearmotor ON time in power 1
Pr06
work phase
Screw feed gearmotor ON time in power 5
Pr07
work phase
Flue gas extraction speed in brazier
Pr08
cleaning phase
Screw feed gearmotor ON time in
Pr09
cleaning phase
Flue gas extractor switch-off threshold (in
Pr10
switch-off phase)
Pr11
Alarm delay
Pr12
Brazier cleaning duration
Flue gas minimum temperature for
Pr13
considering the stove on
Pr14
Flue gas maximum temperature
Flue gas temperature threshold for
Pr15
starting the heat exchangers
Flue gas extraction speed in ignition
Pr16
phase
Pr17
Flue gas extraction speed in start phase
Flue gas extraction speed in power 1 work
Pr18
phase
Flue gas intake speed in power 5 work
Pr19
phase
Heat exchanger 1 motor speed in power 1
Pr20
work phase
Heat exchanger 1 motor speed in power 5
Pr21
work phase
Unit of
Display text
measurement
IGNITION MINUTES
Minutes
START MINUTES
Minutes
CLEANING
Minutes
FREQUENCY
SCREW FEED ON
Seconds
SCREW FEED START
Seconds
P1 SCREW FEED
Seconds
P5 SCREW FEED
Seconds
EXTRACTOR
CLEANING
CLEANING SCREW
Seconds
FEED
THRESHOLD OFF
ALARMS DELAY
Seconds
CLEANING DURATION
Seconds
MINIMUM THRESHOLD
MAXIMUM
THRESHOLD
FAN THRESHOLD
EXTRACTOR ON
EXTRACTOR START
EXTRACTOR P1
EXTRACTOR P5
AIR P1
AIR P5
30
Value field
5 – 25
2 – 20
10 – 255
0.1 – 4.0
0.1 – 4.0
0.1 – 4.0
0.1 – 4.0
RPM
700 – 2800
0.0 – 4.0
°C
50 – 180
20 – 90
0 – 120
°C
35 – 180
°C
60 – 280
°C
50 – 210
RPM
500 – 2800
RPM
500 – 2800
RPM
500 – 2800
RPM
500 – 2800
Volt
65 – 225
Volt
65 – 225
Database o0
20
4
60
1.0
0.8
1.0
2.8
2800
0.8
70
30
50
43
250
60
2200
1900
1400
1900
180
225

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido