Tool Holder - Fein MULTIMASTER FMM250 Manual De Instrucciones

Ocultar thumbs Ver también para MULTIMASTER FMM250:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3 41 01 091 21 0.book Seite 13 Dienstag, 24. Juli 2007 3:32 15
M
M
FMM 250 / M
ULTI
ASTER
M
M
FMM 250 (Figure 4).
ULTI
ASTER
Before mounting or replacing
WARNING
application tools or accesso-
ries, pull the power plug. This preventive
safety measure rules out the danger of inju-
ries through accidental starting of the
power tool.
For all work or when chang-
CAUTION
ing application tools, always
wear protective gloves. Danger of injury
from the sharp edges of the application
tools. Application tools can become very
hot while working. Danger of burns!
Unscrew the clamping screw.
Clean the tool holder, the applica-
tion tool and the clamping screw.
Place the application tool exactly
onto the star-shaped tool holder. Pay
attention that the application tool has a
flush fit.
Tighten the clamping screw using
the supplied Allen key.
Attaching/replacing the sanding sheet (Figure 5).
Align the sanding sheet and press it
onto the sanding plate by hand.
Firmly press the power tool with the
sanding sheet against a flat surface and
briefly switch the power tool on. This
provides for good adhesion and pre-
vents premature wear.
The sanding sheet can be pulled off again
and then remounted offset by 120° when
only one tip of the sanding sheet is worn.
M
FMM 250 Q
ULTI
ASTER
Fig. 4
Fig. 5
Sanding sheet
Sanding pad
Clamping screw

Tool holder

Allen key
EN