Hayward AQUA RITE pro Guia Del Usuario página 32

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
The AquaRite Pro periodically reverses the polarity of the voltage applied
to the cell in order to automatically clean off any calcium deposits that may
have built up on the cell. It is important that you check the chlorinator
operation in both polarities. To do this, press either the "+" or "-" buttons
and the chlorinator will turn off, wait for 15 seconds and then turn on in the
opposite polarity.
Salt Level
3.2 g/L
This is the average "Salt Level" in the pool. This value is calculated over time
and minimizes the effects of spikes or dips that may naturally occur.
Instant Salt
3.2 g/L (+=save)
The "Instant Salt" is calculated based on the voltage, current (amps), and
water temperature at the cell at that instant. There are a number of reasons
why instant and average salt readings may differ. Some of these include salt
having just been added to the pool and not yet thoroughly mixed, calcium
buildup on the cell, and cell aging.
Press the "+" button to enter the instant salt value into the average salt level.
The average salt level will use this new value for its calculations.
Flow Switch
Flow
The current status of the flow switch is displayed. There is a short delay when
transitioning from flow to no-flow and a longer delay on the transition from
no-flow to flow. The delay time is displayed.
Main Software
Revision 1.00
Display Software
Revision 1.00
Chemistry Sense
Software r1.00
Available displays depend on configuration. These displays show the software
revisions of various components.
Inspect Cell
hold + to reset
For optimum operation, you will need to inspect the AquaRite Pro chlorinator
cell approximately every 3 months and clean the cell if necessary. The
AquaRite Pro will automatically remind you and display "Inspect Cell, hold
+ to reset" as part of the rotating Information Menu. Clean the cell and then
press the "+" button during the "Inspect Cell" display to reset the timer.
8 / 20
No Function
Move to previous/next menu item
Press to load the "Instant Salt" into the averaged salt display
Move to previous/next menu item
No Function
Move to previous/next menu item
No Function
Move to previous/next menu item
No Function
Move to previous/next menu item
No Function
Move to previous/next menu item
Press to reset
Move to previous/next menu item
AquaRite Pro
Rev. C

Publicidad

Tabla de contenido
loading

Tabla de contenido