Input Power - Hayward AQUA RITE pro Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
Electrolytic Cell: Install using the unions provided. Tighten unions BY HAND for a watertight
Wiring
Power must be shut off at the circuit breaker before performing any wiring. Be sure to follow
Local electrical codes. To provide safe operation, the AquaRite Pro must be properly grounded.
All metal equipments of the pool must be at the same electrical potential (ground).

Input Power:

Wire the AquaRite Pro to the 230 V from the subpanel.
This circuit must be protected by a differential protection device that protects against
no more than 30ma leakage current.
Input power to the AquaRite Pro must be 230 V. Refer to the wiring label on the AquaRite
Pro as well as the diagram below for correct wiring connections.
AquaRite
PRO
15 / 20
Drill a 17mm hole
into the return pipe
seal. For pool/spa combination systems with spillover, use configurations
#2 or #3 on page 14 to allow chlorination of both the pool and spa during
spillover but preventing overchlorination when operating the spa only.
TyPICAL 230 V WIRING
N
PCB
AquaRite Pro
Line up arrow with
direction of flow
Position the saddle clamp's
rubber seal over hole.
Tighten clamp evenly.
230 V
FROM SUBPANEL
Rev. C

Publicidad

Tabla de contenido
loading

Tabla de contenido