A5 00
Pre-flashing
00
OFF (flashing light only turns on when gate is moving)
01
10
TIME IN SECONDS that the flashing light operates before the gate moves
-
99
not activated during opening; 5 second pre-flashing time before closing
5-
NOTE: parameter
A6 00
Apartment building function on pedestrian command (PED)
00
OFF (pedestrian command runs OP-ST-CL-ST-OP... cycle)
01
ON (pedestrian command is ignored while opening)
A7 00
Hold-to-run
00
OFF (controls work normally)
01
ON (the gate only moves when AP or CH are held down)
The motor only runs while there is a continuous command; the only controls enabled are AP and CH; the
motor stops as soon as the control is released.
The controls must be located where the user can see the gate operating.
A8 00
Gate open light
00
when the gate is closed, the light is off, otherwise it is steadily lit
slow flashing while opening, fast while closing, steadily lit when fully open, turns off 3 times
01
in a row every 15 seconds if the gate is stopped in intermediate position
02
the SC output is used to power the photocells and run the photocell test
11 15
Slow-down distance run by motor 1
12 15
Slow-down distance run by motor 2
01
30
PERCENTAGE of total travel
-
If slow-down is enabled (parameter
a percentage of total distance - will be covered at reduced speed.
WARNING! If you are not using the encoder, you will need to select this option before programming travel.
If you do this after you have finished programming, you will need to repeat the programming procedure.
13 10
Tolerance applied to position in which leaf 1 is deemed fully open or closed
14 10
Tolerance applied to position in which leaf 2 is deemed fully open or closed
01
40
motor speed
-
Determines the maximum tolerance applied when checking the fully open and fully closed position (where
the motors stop). If the tolerance is too tight, there is a danger of movement being reversed when the leaf
reaches the gate stop.
This parameter is only visible if there are no limit switches installed (
75 01
enabled (
or
15 99
Pedestrian travel distance
01
99
PERCENTAGE of total travel
-
The factory default setting for a double-leaf gate is for leaf 1 to open fully. For a single-leaf gate, the default
50
setting is
.
in easy setup mode
41
has a value other than
75 02
).
00
), it determines how much distance - as
72 00
72 02
or
) and the encoder is
35