50 00
Mode if FT1 photocell beam is broken while opening
00
IGNORE, no action or FT1 not installed
01
STOP, the gate stays where it is until it receives a new command
02
REVERSE IMMEDIATELY, hence the gate closes
03
TEMPORARY STOP, once the beam is clear, the gate will continue opening
04
REVERSE WHEN CLEAR, once the beam is clear, movement is reversed, hence the gate closes
51 02
Mode if FT1 photocell beam is broken while closing
00
IGNORE, no action or FT1 not installed
01
STOP, the gate stays where it is until it receives a new command
02
REVERSE IMMEDIATELY, hence the gate opens
03
TEMPORARY STOP, once the beam is clear, the gate will continue closing
04
REVERSE WHEN CLEAR, once the beam is clear, movement is reversed, hence the gate opens
52 01
With gate closed, enable opening with FT1 beam broken
00
gate not allowed to open
01
gate allowed to open
02
OPEN WHEN BEAM BROKEN
53 03
Mode if FT2 photocell beam is broken while opening
00
IGNORE, no action or FT2 not installed
01
STOP, the gate stays where it is until it receives a new command
02
REVERSE IMMEDIATELY, hence the gate closes
03
TEMPORARY STOP, once the beam is clear, the gate will continue opening
04
REVERSE WHEN CLEAR, once the beam is clear, movement is reversed, hence the gate closes
54 04
Mode if FT2 photocell beam is broken while closing
00
IGNORE, no action or FT2 not installed
01
STOP, the gate stays where it is until it receives a new command
02
REVERSE IMMEDIATELY, hence the gate opens
03
TEMPORARY STOP, once the beam is clear, the gate will continue closing
04
REVERSE WHEN CLEAR, once the beam is clear, movement is reversed, hence the gate opens
55 01
With gate closed, enable opening with FT2 beam broken
00
gate not allowed to open
01
gate allowed to open
02
OPEN WHEN BEAM BROKEN
56 00
With gate fully open, close 6 seconds after photocell beam is broken
00
OFF (no action taken when photocell beam is broken)
01
break in FT1 closes gate
02
break in FT2 closes gate