Software Parameters, cont'd
Parameter
Signal Input #1 (S1) Setup
30
S1 Input Configuration
31
S1 Setpoint
Signal Input #2 (S2) Setup
35
S2 Input Configuration
36
S2 Setpoint
Alarm Output Configuration
40
Activation Conditions
41
Output Style & Reset Mode
42
Reset Configuration
43
Display Flash On Active Alarm
44
Pulse on Time
45
Pulse off Time
46
Pulse Count
47
Lower Limit
48
Upper Limit
Parameter Memory Commands
95
Restore Settings to Factory Default
98
Save to User Default Area
99
Restore from User Default Area
Description
10
Value Range
(units)
1 – Output 0% When S1 Low
2 – Output 0% When S1 High
3 – Output Setpoint When S1 Low
4 – Output Setpoint When S1 High
5 – Output 100% When S1 Low
6 – Output 100% When S1 High
-9999 – 9999 (Display Units)
1 – Output 0% When S2 Low
2 – Output 0% When S2 High
3 – Output Setpoint When S2 Low
4 – Output Setpoint When S2 High
5 – Output 100% When S2 Low
6 – Output 100% When S2 High
-9999 – 9999 (Display Units)
0 – Always Off
1 – Always On
2 – Active when Above upper limit
3 – Active when Below lower limit
4 – Active inside Range
5 – Active outside Range
6 – Active Zero or Equivalent Output
7 – Relay Direction Control Mode
1 – Constant & Auto Reset
2 – Constant & Manual Reset
3 – Pulsed & Auto Reset
4 – Pulsed & Manual Reset
1 – No Sil., Reset on Key
2 – No Sil., Reset on S2 High
3 – No Sil., Reset on S2 Low
4 – Sil., Reset on Key
5 – Sil., Reset on S2 High
6 – Sil., Reset on S2 Low
0 – Alarm Flash Disabled
1 – Alarm Flash Enabled
1 – 3600 (seconds)
1 – 3600 (seconds)
0 – 9999 (pulses)
0 – 9999 (display units)
0 – 9999 (display units)
0 – Do Nothing & Exit
5 – Restore Factory Defaults
0 – Do Nothing & Exit
5 – Save Setting
0 – Do Nothing & Exit
1 – Restore Settings
Factory
User
Default
Settings
1
0
1
0
0
1
1
0
1
1
0
0
9999
0
0
0